Yaskawa MP2000 User Manual

Page 75

Advertising
background image

TECHNICAL NOTE


Input Registers
The following registers are used as inputs to the function block. They select the options
and define the parameters that the user needs to make the function work as necessary.

File: MP2000_IndividualFunctionDocument_RevC 75/168
Doc Number: eng.MCD.05.101

11/17/2005

INPUT

TYPE

Content

Range and state

EXECUTE Bit

Block enable – Block cannot
execute unless this is TRUE

Rising edge initiates block
TRUE – Block enable
FALSE – Block disable, set
all outputs to zero and off

AXIS

Word

Axis number related to the
block

1~16

DISTSTRT Long

Sets the beginning of the
latch activation window.
Defined as distance in
counts from the start
position of the axis. Latch is
armed between DISTSTRT
and DISTEND.

2147483648~2147483647

DISTEND Long

Sets the end of the latch
activation window. Defined
as distance in counts from
the start position of the axis.
Latch is armed between
DISTSTRT and DISTEND.

2147483648~2147483647

DFLTDIST Long

Default distance to travel in
counts from the start
position of the axis. This is
the relative distance the axis
will travel if a latch is not
detected

2147483648~2147483647

DISTBYND Long

Distance to travel in counts
from the Latch position.
This is the additional relative
distance the axis will travel
(from the latch detection
position) if a latch is
detected.

2147483648~2147483647

LTSEL

Word

Latch detection signal
selection

0: C phase pulse signal
1: /EXT1 (servo amplifier DI)
2: /EXT2 (servo amplifier DI)
3: /EXT3 (servo amplifier DI)

DATA11W

Address

Address of the first working
register.

Eleven words of register
space are used by this
function.

Advertising