TECHNICAL NOTE

Input register

The following registers are used as inputs to the function block. They select the options
and define the parameters that the user needs to make the function work as necessary.

Input

Type

Description

Range of state

ENABLE

Bit

Block enable – Block cannot
execute unless this is TRUE

Rising edge initiates block
TRUE – Block enable
FALSE – Block disable, set
all outputs to zero and off

EXECUTE Bit

Starts the Modulus engine,
modulates the master
counter input.

Rising edge starts block
modulation
TRUE – modulation active
FALSE – holds the
modulated data

RESET

Bit

Sets the Modulated data to
zero, also active when
EXECUTE is on.

TRUE – Mod Data = 0
FALSE – Modulus engine
free to run

M-S-PAIR Word

Defines which Master-Slave
pair is updated in RDA

1 to 10 value. Any other
value will cause the error
output to go on.

MCHNCYC
L

Long

Highest value in modulated
data

1~2147483647

RAWDATA Long

Input to be modulated (feed
virtual counter or encoder
here)

2147483648~2147483647

DATA14W

Address

Address of the first working
register.

Fourteen words of register
space are used by this
function.