Input register – Yaskawa MP2000 User Manual
Page 80
 
TECHNICAL NOTE
Input register
The following registers are used as inputs to the function block. They select the options 
and define the parameters that the user needs to make the function work as necessary. 
Input
Type
Description
Range of state
ENABLE
Bit
Block enable – Block cannot 
execute unless this is TRUE 
Rising edge initiates block 
TRUE – Block enable 
FALSE – Block disable, set 
all outputs to zero and off 
EXECUTE Bit
Starts the Modulus engine, 
modulates the master 
counter input. 
Rising edge starts block 
modulation 
TRUE – modulation active 
FALSE – holds the 
modulated data 
RESET
Bit
Sets the Modulated data to 
zero, also active when 
EXECUTE is on. 
TRUE – Mod Data = 0 
FALSE – Modulus engine 
free to run 
M-S-PAIR Word
Defines which Master-Slave 
pair is updated in RDA 
1 to 10 value. Any other 
value will cause the error 
output to go on. 
MCHNCYC
L 
Long
Highest value in modulated 
data 
1~2147483647
RAWDATA Long
Input to be modulated (feed 
virtual counter or encoder 
here) 
2147483648~2147483647
DATA14W
Address
Address of the first working 
register. 
Fourteen words of register 
space are used by this 
function. 
File: MP2000_IndividualFunctionDocument_RevC 80/168 
Doc Number: eng.MCD.05.101 
11/17/2005