TECHNICAL NOTE

<MOVINC> Input and Output Register Map


Output Registers
The following registers are used as outputs from the function block. They can be
monitored by the LadderWorks program to check the execution of the function.

Output

Type

Description

RUNNING

Bit

High while block has control and move is in
progress..

DONE

Bit

Indicates Move Complete. When the servo
has reached target position within “In-
position” window ON (IB**0C1=ON), this
output bit turns.

ERROR

Bit

Latches high if any error occurs in block (see
table below) or on the servo axis (see IL**04).

DISTGONE

Long

Distance in counts block has traveled in this
move, while this block has control.










Input Registers
The following registers are used as inputs to the function block. They select the options
and define the parameters that the user needs to make the Home function work as
necessary.

Input

Type

Description

Range and state

EXECUTE Bit

Block enable – Block cannot
execute unless this is
TRUE.

Rising edge initiates
TRUE – Block enable
FALSE – Block disable, set
all outputs to zero and off

AXIS

Word

Axis number related to the
block.

1~16

DISTANCE Long

Relative distance to travel in
counts to complete move.

-2147483648~2147483647

DATA08W

Address

Address of the first working
register.

Eight words of register space
are used by this function.

File: MP2000_IndividualFunctionDocument_RevC 92/168