5.3 Numeric Operation Instructions
5.3.23 ASCII Conversion 3 (ASCBIN)
5-62
( 3 ) Programming Example
In the following programming example, the ASCBIN instruction is used to store the input data in MW00000 in the out-
put data in MW00002.
The ASCII values are stored as given in the following table.
The output data in MW00000 is set to 10,811 (2A3B hex).
Address
ASCII Value
Character
MW00000 (lower byte)
32 hex
2
MW00000 (upper byte)
41 hex
A
MW00001 (lower byte)
33 hex
B
MW00001 (upper byte)
42 hex
3