12 linear accelerator/decelerator 2 (slau), 1 ) operation – Yaskawa MP900 Series Ladder Programming Manual User Manual

Page 253

Advertising
background image

5.8 DDC Instructions

5.8.12 Linear Accelerator/Decelerator 2 (SLAU)

5-184

5.8.12 Linear Accelerator/Decelerator 2 (SLAU)

( 1 ) Operation

The SLAU instruction outputs the speed that results from applying a variable acceleration or deceleration rate to the
input speed. Operation for the acceleration or deceleration rate is performed in an S curve according to predefined
parameters in a parameter table.
The input value to the SLAU instruction can be an integer or a real number.
The structure of the parameter table depends on the data type.

Œ

Double-length integers can be used only for CPU software version 2.30 or higher. For earlier versions, the lower 16
bits of the double-length integer are used in the calculations as an integer.

100% level of input

Acceleration/deceleration rate set in parameters

Input speed

Input speed

SLAU instruction

input speed waveform

Time (t)

SLAU instruction

output speed waveform

Time (t)

Acceleration time +

Acceleration S-curve time

(AT + AAT)

Deceleration time +

Deceleration S-curve time

(BT + BBT)

Advertising