2.1 MP2000-series Machine Controller Specifications

2.1.2 Machine Controller Program Specifications

2-3

Specifications for Ladder Programs

2

2.1.2 Machine Controller Program Specifications

∗ 1. This is the total capacity for ladder programs and motion programs.
∗ 2. This is supported only for version 2.66 or higher.
∗ 3. The # registers can be used only when ladder programs are used.

Machine Controller

MP2100
and
MP2100M

MP2300

MP2300S

MP2200
with
CPU-01

MP2310

MP2200
with
CPU-02

MP2101, MP2101M,
MP2101T, MP2101TM,
MP2200 with CPU-03,
MP2200 with CPU-04,
and MPU-01

Program Capacity

*1

5.5 MB

7.5 MB

11.5 MB

La

dder Prog

ra

ms

Applicable Models

Applicable

*2

NA

Applicable

Startup Processing

64 drawings max. including parent drawings, operation error drawings, child drawings, and grandchild drawings

Interrupt
Processing

64 drawings max. including parent drawings, operation error drawings, child drawings, and grandchild drawings

High-speed Scan
Processing

200 drawings max. including parent drawings, operation error drawings, child drawings, and grandchild draw-
ings

Low-speed Scan
Processing

500 drawings max. including parent drawings, operation error drawings, child drawings, and grandchild draw-
ings

User Functions

500 drawings max.

Maximum Number
of Steps

1,000 steps per drawing

Moti

on Pro

grams

Applicable Models

Applicable

Number of
Programs

256 programs max. including motion programs and sequence programs

Number of Groups

8 groups (Up to 16 axes can be set in one group.)

Number of Tasks

16 tasks max. (This is the number of simultaneously executable motion programs.)

Number of Parallel
Forks per Task

8 (4 main program forks

× 2 subprogram forks)

Sequ

ence Pro

g

rams

Applicable Models

NA

Applicable Applicable

NA

Applicable

NA

Applicable

Number of
Programs

256 programs max. including motion programs and sequence programs

Number of Tasks

16 tasks max. (This is the number of simultaneously executable sequence programs.)

Acce

ssi

ble

Regi

sters

M Registers

Applicable (65,535 words)
These registers are backed up with a battery.

*3

S Registers

Applicable (8,192 words)
These registers are backed up with a battery.

*3

I Registers

Applicable (32,768 words + motion monitor parameters)

O Registers

Applicable (32,768 words + motion setting parameters)

C Registers

Applicable (16,384 words)

D Registers

Applicable (Can be specified to between 0 and 16,384 words.)
These registers are unique to each drawing (DWG). They can be used within each drawing.

# Registers

Applicable (Can be specified to between 0 and 16,384 words.)
These are internal registers that are unique to each drawing (DWG). They can be referenced within each draw-
ing.

Capacity of Table Data
Backed Up by a Battery

None

1 MB

3 MB