3 ) programming example – Yaskawa MP900 Series Ladder Programming Manual User Manual
Page 239
Advertising

5.8 DDC Instructions
5.8.9 Function Generator (FGN)
5-170
( 3 ) Programming Example
In the following programming example, the function is generated using the FGN instruction for real numbers with the
parameter table given below.
The following figure shows the relationship between input value X in MF00000 and output value Y in MF00002.
Number of Pairs
4
X1, Y1
0.0, 2.0
X2, Y2
10.0, 6.0
X3, Y3
20.0, 15.0
X4, Y4
30.0, 20.0
Input value X:
MF00000
Output value Y:
MF00002
0.0
10.0
20.0
30.0
2.0
6.0
15.0
20.0
X1, Y1
X2, Y2
X3, Y3
X4, Y4
Advertising
This manual is related to the following products: