10 set coil (s-coil), 1 ) operation, 2 ) format – Yaskawa MP900 Series Ladder Programming Manual User Manual
Page 89: 3 ) programming example
Advertising

5.2 Relay Circuit Instructions
5.2.10 Set Coil (S-COIL)
5-20
5.2.10 Set Coil (S-COIL)
( 1 ) Operation
The S-COIL instruction sets the value of the bit at the coil address to 1 (ON) when the bit input is 1 (ON). The set coil
stays in the ON state.
( 2 ) Format
∗ C and # registers cannot be used.
( 3 ) Programming Example
The DB000001 set coil stays in the ON state when the DB000000 relay turns ON.
The timing chart is shown below.
Bit input
Coil address
1 (ON)
0 (OFF)
1 (ON)
0 (OFF)
Bit value
Coil address
Icon:
Key entry: @S
Parameter Name
Applicable Data Types
B
W
L
F
A
Index
Constant
Coil address
{
*
×
×
×
×
×
×
DB000000
ON
OFF
ON
OFF
DB000001
Advertising