5.10 System Function Instructions

5.10.3 Trace (TRACE)

5-232

5.10.3 Trace (TRACE)

( 1 ) Operation

The TRACE instruction performs trace execution control of the trace data that is specified by the trace group number (1
to 4).

Œ

The trace definition is set in the Data Trace Definitions in the MPE720. Refer to the Engineering Tool for MP2000
Series Machine Controller MPE720 Version 6 User’s Manual
(SIEP C880700 30) for details.

• The trace is executed if Execute (trace execution command) is ON.
• The trace counter is reset when Reset (trace reset command) turns ON. This also resets Trc-End (trace end).
• Trc-End (trace end) turns ON when the specified number of traces have been executed.

( 2 ) Format

∗ C and # registers cannot be used.

Error

Status

TRACE execution command

ON

TRACE reset command

ON

Trace is executed.

Trace count reset
Trace end reset

Trace execution count = Set value
→ Trace end

TRACE instruction

Trace definition

Trace group No.

Set on the MPE720.

Parameter Name

Applicable Data Types

B

W

L

F

A

Index

Constant

Trace execution command
(Execute)

{

×

×

×

×

×

×

Trace reset command
(Reset)

{

×

×

×

×

×

×

Trace group No. (Group-No)

×

{

×

×

×

{

{

Trace end (Trc-End)

{

*

×

×

×

×

×

×

Error

{

*

×

×

×

×

×

×

Status

×

{

*

×

×

×

{

×

Icon:

Key entry: TRACE