5.10 System Function Instructions

5.10.10 Write SERVOPACK Parameter (MLNK-SVW)

5-272

„

Processing Result (PARAM00)

• 0000 hex: Processing (Busy)
• 1000 hex: Processing completed (Complete)
• 8††† hex: Error

The following errors can occur.

• 8100 hex:

Reserved.

• 8200 hex:

Address setting error
The set data address is outside of the valid range.

• 8300 hex:

Reserved.

• 8400 hex:

Circuit number setting error
The set circuit number is outside of the valid range.

• 8500 hex:

Reserved.

• 8600 hex:

Axis number setting error
The set axis number is outside of the valid range.

• 8700 hex:

Reserved.

• 8800 hex:

Communications interface task error
An error was returned from the communications interface task.

• 8900 hex:

Reserved.

• 8A00 hex: Function execution duplication error

More than one MLNK-SVW function was executed at the same time.

„

Error Code (PARAM01)

This parameter outputs the error code from the communications interface task. This parameter is valid only when
the processing result (PARAM00) is 8800 hex.

• 0000 hex: Reserved.
• 0001 hex: No SERVOPACK parameter backup file
• 0002 hex: Backup file error
• 0003 hex: Inconsistent ID information
• 0004 hex: Inconsistent version
• 0005 hex: Module error
• 0006 hex: SERVOPACK controller command duplication error
• 0007 hex: Communications error
• 0008 hex: Undefined command
• 0009 hex: Invalid parameter
• 000A hex: Internal system error

„

Copy of Cir-No (PARAM02)

This is a copy of the Cir-No input data.

„

Copy of St-No (PARAM03)

This is a copy of the St-No input data.

„

For System Use #1 (PARAM04)

This parameter is used by the system. Set this parameter to 0000 hex from a user program in the first scan after
the power supply is turned ON. Do not modify this parameter at any other time.