3 ) programming example – Yaskawa MP900 Series Ladder Programming Manual User Manual
Page 299
5.10 System Function Instructions
5.10.2 First-in First-out (FINFOUT)
5-230
The parameters are described in the following table.
( 3 ) Programming Example
In the following programming example, a FIFO table is created with a data size of 12 words, input size of 4 words, and
an output size of 2 words, and then the FINFOUT instruction is executed.
Parameter Name
Description
I/O
Data input command (In-Cmd)
Data is stored in the FIFO table when this command turns
ON.
IN
Data output command (Out-Cmd)
Data is transferred out of the FIFO table when this com-
mand turns ON.
IN
Reset command (Reset)
The number of words to store is set to 0 when this command
turns ON.
IN
First address of FIFO table (FIFO-Tbl)
+0 word: Data size
IN
+1 word: Input size
IN
+2 word: Output size
IN
+3 word: Data storage size
OUT
+4 word and on: Data
OUT
First address of input data (In-Data)
First address of input data
IN
First address of output data (Out-Data)
First address of output data
IN
FIFO table full (Tbl-Full)
Turns ON when the FIFO table is full.
OUT
FIFO table empty (Tbl-Emp)
Turns ON when the FIFO table is empty.
OUT
FIFO table error (Tbl-Err)
Turns ON when the FIFO table has an error.
OUT