5.8 DDC Instructions

5.8.7 First-order Lag (LAG)

5-163

Instructions

5

( 3 ) Programming Example

In the following programming example, the LAG instruction is executed where MF00000 is the input value in the
parameter table, MF00002 is the output value, and the first-order lag time constant is set to 1.0.

MF00002 changes as shown below when the input value (MF00000) changes from 0 to 10,000.

MF00002 changes as shown below when the input value (MF00000) changes from 0 to -10,000.

0

10,000

Approx. 6,300

1.0 s

Input value

(MF00000)

Output value

(MF00002)

0

-10,000

Approx. -6,300

Input value

(MF00000)

Output value

(MF00002)

1.0 s