5.8 DDC Instructions

5.8.5 PD Control (PD)

5-151

Instructions

5

( 2 ) Format

∗ C and # registers cannot be used.

[ a ] Parameter Table Configuration for PD Instruction with Integers

∗ The relay input and output bits are assigned as given below.

First address of

parameter table

Output value

Input value

Icon:

Key entry: PD

Parameter Name

Applicable Data Types

B

W

L

F

A

Index

Constant

Input value (In)

×

{

×

{

×

{

{

First address of
parameter table (Prm)

×

×

×

×

{

*

{

{

Output value (Out)

×

{

*

×

{

*

×

{

×

Address

Data

Type

Symbol

Name

Specification

I/O

0

W

RLY

Relay I/O

Relay inputs and relay outputs

*

IN/OUT

1

W

Kp

P gain

Gain for the P compensation
(A gain of 1 is equivalent to 100.)

IN

2

W

Kd

D gain

Gain for the input to the differential circuit
(A gain of 1 is equivalent to 100.)

IN

3

W

Td1

Differential time for
divergence

Differential time used when the input diverges (ms)

IN

4

W

Td2

Differential time for
convergence

Differential time used when the input converges (ms)

IN

5

W

UL

PD upper limit

Upper limit for the P + D compensation

IN

6

W

LL

PD lower limit

Lower limit for the P + D compensation

IN

7

W

DB

PD output dead zone

Dead zone width for the P + D compensation

IN

8

W

Y

PD output

PD compensation output (output to Out)

OUT

9

W

X

Input value storage

Storage of current input value

OUT

Bit

Symbol

Name

Specification

I/O

0 to 7

(Reserved.)

Spare input relays

IN

8 to F

(Reserved.)

Spare output relays

OUT