8 write inverter parameter (icns-wr), 1 ) operation – Yaskawa MP900 Series Ladder Programming Manual User Manual

Page 330

Advertising
background image

5.10 System Function Instructions

5.10.8 Write Inverter Parameter (ICNS-WR)

5-261

Instructions

5

5.10.8 Write Inverter Parameter (ICNS-WR)

( 1 ) Operation

The ICNS-WR instruction writes data to parameters in an Inverter. You can specify the types and range of the parame-
ters in the Inverter.

Applicable Inverters:
This instruction is applicable to Inverters that are connected to the MP930, SVB-01, or 215IF.

Data 1

Data 2

:

Data 10

First address of parameter list

Number of parameters

to write

(1 to 100)

ASR Proportional

Gain

ASR Integral Time

:

PG Dividing Ratio

:

:

Acceleration Time 1

Bn-06

Bn-05

Bn-14

Bn-01

Written.

M, D, or # registers

Parameters in the Inverter

Parameter type

Parameter number

Advertising