( 1 ) Operation
The ICNS-WR instruction writes data to parameters in an Inverter. You can specify the types and range of the parame-
ters in the Inverter.
Applicable Inverters:
This instruction is applicable to Inverters that are connected to the MP930, SVB-01, or 215IF.
Data 1
Data 2
:
Data 10
First address of parameter list
Number of parameters
to write
(1 to 100)
ASR Proportional
Gain
ASR Integral Time
:
PG Dividing Ratio
:
:
Acceleration Time 1
Bn-06
Bn-05
Bn-14
Bn-01