A.10 Module Information

The Module information is reported as shown in this section.

Œ

The contents of the registers depends on the model. Refer to the manuals for your Machine Controller.

( 1 ) CPU Function Module

( 2 ) Option Modules

( 3 ) Function Module Status Details

Name

Register Address

Remarks

CPU Unit Information

SW00800

CPU Module ID

SW00801

Hardware version (BCD)

SW00802

Software version (BCD)

SW00803

Number of sub-slots (hex)

SW00804

Function Module 1 ID (hex)

SW00805

Function Module 1 Status

SW00806

Function Module 2 ID (hex)

SW00807

Function Module 2 Status

SW00808

Function Module 3 ID (hex)

SW00809

Function Module 3 Status

SW00810

Function Module 4 ID (hex)

SW00811

Function Module 4 Status

SW00812

Function Module 5 ID (hex)

SW00813

Function Module 5 Status

SW00814

Function Module 6 ID (hex)

SW00815

Function Module 6 Status

Option Module Information

SW00816 to SW01095

Option Module Information
(Depends on the CPU model and mounted Option Modules.)

Name

Register Address

Remarks

Module
Information

SW00††† + 0

Option Module ID

SW00††† + 1

Hardware version (BCD)

SW00††† + 2

Software version (BCD)

SW00††† + 3

Number of sub-slots (hex)

SW00††† + 4

Function Module 1 ID (hex)

SW00††† + 5

Function Module 1 Status

SW00††† + 6

Function Module 2 ID (hex)

SW00††† + 7

Function Module 2 Status

Value

Text Displayed in MPE720

Module Configuration

Definition

Status

0

None

There is no Module Definition and the Module is not mounted.

1

Empty

There is a Function Module Definition, but the Module is not mounted.

2

Operating (Driving)

The Module is operating normally.

3

Standby
(Reserved for system.)

The Module is on standby.

4

Failure

An error was detected in the Module.

5

× Module name

The mounted Module does not match the definition.

6

Waiting for initialization

The Module is mounted, but there is no Detailed Function Module Definition.

7

Driving stop

Local I/O is stopped.

8 or higher –

Reserved for system.