1.2 Features of Ladder Programming for MP2000-series Machine Controllers

1.2.4 Communications Control with External Devices

1-5

Introduction to Ladder Programming

1

1.2.4 Communications Control with External Devices

The MSG-SND and MSG-RCV ladder instructions support various protocols and can be used to control communica-
tions with many external devices, such as a touch panels or host PLCs. This allows external devices to access registers
in the Machine Controller.

Instead of using a ladder program, the Machine Controller can also communicate with external devices by using I/O message
communications or automatic reception.
Refer to Chapter 6 Ethernet Communications in the Machine Controller MP2310 Basic Module User’s Manual (Manual No.:
SIEP C880732 01) for details.

1.2.5 Complete Synchronization with Motion Control

Ladder programs that are started in the high-speed scan are processed in complete synchronization with motion control
processing. This allows you to call and process a motion program that performs complicated motion control synchro-
nously with a ladder program.

MP2000-series Machine Controller

• MSG-SND instruction

(Send Message)

• MSG-RCV instruction

(Receive Message)

Ladder Program

Touch Panel

PLC

Registers

External Device

INFO

Sequence Control

Ladder Program (High-speed Scan)

Motion control is processed in

complete synchronization with

the high-speed scan.

Motion Control

(Motion Module)

Completely

synchronized

control

Position

control

Speed

control

Torque
control

Motion parameters

Motion Program

Setting

motion

parameters

Start of a Motion

Program

Advertising