5.10 System Function Instructions

5.10.5 Read Inverter Trace (ITRC-RD)

5-238

5.10.5 Read Inverter Trace (ITRC-RD)

( 1 ) Operation

The ITRC-RD instruction reads trace data in the Inverter and stores it in registers. You can specify the required records
and read them from the trace buffer. You can designate and read only the required items in each record.

Applicable Inverters:
This instruction is applicable to Inverters that are connected to the MP930, SVB-01, or 215IF.

„

Structure of Read Data

The length of a record can be from 1 to 16 words, depending on the selected data items.
The maximum number of records is 120.

Œ

Records are always read from the first record.

Read data

First address

Specified read

items read.

Data trace memory

Number of

records to read

Old

New

First record

M or D registers

Record 1

Item 1

:
:

Item 16

Record 2

:

Record n

Old

1,920 words max.

New

1 to 16 words

1 to 16 words

1 to 16 words

First address