background image

5.10 System Function Instructions

5.10.11 Write Motion Register (MOTREG-W)

5-275

Instructions

5

5.10.11 Write Motion Register (MOTREG-W)

( 1 ) Operation

The MOTREG-W instruction calls a function that accesses a specified motion register.
The data is written to the motion register by specifying the circuit number, axis number, and register address. This
instruction is used with setting parameters.

Œ

This function is useful to store the same setting parameter for multiple axes with different circuit and axis num-
bers.
To store data with the STORE or EXPRESSION instructions, you need to consider an offset to address the cir-
cuit and the axis numbers.

Setting parameters for the specified

circuit and axis numbers

OW††00

:

:

OL††1C

Write data

Write destination

register address ( = 001C hex)

Advertising