Chapter 4 Explanation of Functions

4.2.36 Automatic carrier frequency reduction

b089: Automatic carrier frequency
reduction selection
b083: Carrier frequency setting

Related code

- The automatic carrier frequency reduction function automatically
reduces the carrier frequency according to the increase in output current.
- To enable this function, specify "01" for automatic carrier frequency
reduction selection (b089).

Item

Function code

Range of data

Description

Automatic carrier
frequency reduction

b089

00/01

00: invalid, 01: valid

- When the output current increases to 60%, 72%, 84%, or 96% of the rated current, this function reduces
the carrier frequency to 12, 9, 6, or 3 kHz, respectively. This function restores the original carrier frequency
when the output current decreases to 5% lower than each reduction start level.

Carrier frequency reduction start level

(Restoration level)

Carrier frequency after

reduction (kHz)

Less than 60% of rated current

15.0

60% (55%) of rated current

12.0

72% (67%) of rated current

9.0

84% (79%) of rated current

6.0

96% (91%) of rated current

3.0

15.0kHz

60%

Output current (%)

Carrier frequency

12.0kHz

9.0kHz

6.0kHz

3.0kHz

72% 84% 96%

0 100

50

- The rate of carrier frequency reduction is 2 kHz per second.
- The maximum limit of carrier frequency change by this function is the value specified for the carrier
frequency setting (b083); the minimum limit is 3 kHz.

Note: If 3 kHz or less frequency has been specified for b083, this function is disabled regardless of the