Chapter 8 List of Data Settings

8 - 9

Default

Code

Function name

Monitored data or setting

_FF _FEF _FUF

Setting

during

operation

(allowed

or not)

Change

during

operation

(allowed

or not)

Page

C001

Terminal [1] function (*2)

18

(*2)

¯

{

C002

Terminal [2] function

16

¯

{

C003

Terminal [3] function (*2)

06

(*2)

¯

{

C004

Terminal [4] function

11

¯

{

C005

Terminal [5] function

09

¯

{

C006

Terminal [6] function

03 03 13

¯

{

C007

Terminal [7] function

02

¯

{

C008

Terminal [8] function

01 (RV: Reverse RUN), 02 (CF1: Multispeed 1 setting), 03 (CF2: Multispeed 2
setting), 04 (CF3: Multispeed 3 setting), 05 (CF4: Multispeed 4 setting), 06 (JG:
Jogging), 07 (DB: external DC braking), 08 (SET: Set 2nd motor data), 09 (2CH:
2-stage acceleration/deceleration), 11 (FRS: free-run stop), 12 (EXT: external trip),
13 (USP: unattended start protection), 14: (CS: commercial power source enable),
15 (SFT: software lock), 16 (AT: analog input voltage/current select), 17 (SET3: 3rd
motor control), 18 (RS: reset), 20 (STA: starting by 3-wire input), 21 (STP: stopping
by 3-wire input), 22 (F/R: forward/reverse switching by 3-wire input), 23 (PID: PID
disable), 24 (PIDC: PID reset), 26 (CAS: control gain setting), 27 (UP: remote
control UP function), 28 (DWN: remote control DOWN function), 29 (DWN: remote
control data clearing), 31 (OPE: forcible operation), 32 (SF1: multispeed bit 1), 33
(SF2: multispeed bit 2), 34 (SF3: multispeed bit 3), 35 (SF4: multispeed bit 4), 36
(SF5: multispeed bit 5), 37 (SF6: multispeed bit 6), 38 (SF7: multispeed bit 7), 39
(OLR: overload restriction selection), 40 (TL: torque limit enable), 41 (TRQ1: torque
limit selection bit 1), 42 (TRQ2: torque limit selection bit 2), 43 (PPI: P/PI mode
selection), 44 (BOK: braking confirmation), 45 (ORT: orientation), 46 (LAC: LAD
cancellation), 47 (PCLR: clearance of position deviation), 48 (STAT: pulse train
position command input enable), 50 (ADD: trigger for frequency addition [A145]), 51
(F-TM: forcible-terminal operation), 52 (ATR: permission of torque command input),
53 (KHC: cumulative power clearance), 54 (SON: servo-on), 55 (FOC: forcing), 56
(MI1: general-purpose input 1), 57 (MI2: general-purpose input 2), 58 (MI3:
general-purpose input 3), 59 (MI4: general-purpose input 4), 60 (MI5:
general-purpose input 5), 61 (MI6: general-purpose input 6), 62 (MI7:
general-purpose input 7), 63 (MI8: general-purpose input 8), 65 (AHD: analog
command holding), 66 (CP1: multistage position settings selection 1 ), 67 (CP2:
multistage position settings selection 2), 68 (CP3: multistage position settings
selection 3), 69 (ORL: Zero-return limit function), 70 (ORG: Zero-return trigger
function), 71 (FOT: forward drive stop), 72 (ROT: reverse drive stop), 73 (SPD:
speed / position switching), 74 (PCNT: pulse counter), 75 (PCC: pulse counter
clear), no (NO: no assignment)

01

¯

{

4-46

C011

Terminal [1] active state

00 (NO) / 01 (NC)

00

¯

{

C012

Terminal [2] active state

00 (NO) / 01 (NC)

00

¯

{

C013

Terminal [3] active state

00 (NO) / 01 (NC)

00

¯

{

C014

Terminal [4] active state

00 (NO) / 01 (NC)

00

¯

{

C015

Terminal [5] active state

00 (NO) / 01 (NC)

00

¯

{

C016

Terminal [6] active state

00 (NO) / 01 (NC)

00

¯

{

C017

Terminal [7] active state

00 (NO) / 01 (NC)

00

¯

{

C018

Terminal [8] active state

00 (NO) / 01 (NC)

00

¯

{

In

te

lligent

input t

e

rm

inals

C019

Terminal [FW] active state

00 (NO) / 01 (NC)

00

¯

{

4-47

*2

When the emergency stop function is enabled (SW1 = ON), "18" (RS) and "64" (EMR) are forcibly written to parameters "C001" and "C003", respectively. (You cannot arbitrarily write "64" to
"C001".) If the SW1 signal is turned off and then turned on, "no" (no assignment) is set in parameter "C003".