Chapter 4 Explanation of Functions

4.3.14 Multistage position switching function (CP1/CP2/CP3)

- When functions "66" (CP1) to "68" (CP3) are assigned to terminal [1] function (C001) to terminal [8]
function (C008), you can select a position setting from multistage positions 0 to 7.
- Use multistage position settings 0 to 7 (P060 to P067) for the position settings.
-

If no position settings are assigned to terminals, multistage position setting 0 (P060) is assumed.

Position

setting CP3 CP2 CP1

Multistage position setting 0

0

0

0

Multistage position setting 1

0

0

1

Multistage position setting 2

0

1

0

Multistage position setting 3

0

1

1

Multistage position setting 4

1

0

0

Multistage position setting 5

1

0

1

Multistage position setting 6

1

1

0


- You can specify a delay to be applied at multistage position setting input, until the relevant terminal input
is determined. Use this specification to prevent the application of fluctuating terminal input before it is
determined.
- You can adjust the determination time with the multistage speed/position determination time setting
(C169). The input data is finally determined when the terminal input becomes stable after the delay set as
C169. (Note that a long determination time deteriorates the input terminal response.)

CP1

CP2

CP3

Position command

Determination time (C169) specified

4

1

5

3

Determination time (C169) = 0

7














4 - 11

1

4.3.15 Speed/position switching function (SPD)

Determination time

(C169)

- To perform speed control operation in absolute position control mode, turn on the SPD terminal.
- While the SPD terminal is off, the current position count remains at 0. Therefore, if the SPD terminal is
turned off during operation, the control operation is switched to position control operation based on the
position where the terminal is turned off. (Speed control operation is switched to position control
operation.)
- If the position setting is 0 at this time, the inverter stops the motor at that position.
(Hunting may occur if a certain position loop gain value has been set.)
- While the SPD terminal is on, the rotating direction depends on the operation command. When
switching from speed control to position control, pay attention to the sign of the value set in the operation
command.

Output frequency

Position control

Speed control

Time

Start of position counting

Target position

ON

SPD terminal