Chapter 4 explanation of functions, Ix) list of registers (3rd control setting) – Hitachi SJ700-2 User Manual

Page 230

Advertising
background image

Chapter 4 Explanation of Functions

4 - 167

(viii) List of registers (3rd control settings)

Register

No.

Function name

Function code

R/W Monitoring and setting items Data resolution

Register

No.

3103h F302

(high)

R/W

3104h

Acceleration (1) time setting, 3rd
motor

F302 (low)

R/W

1 to 360000

0.01 [sec.]

3105h F303

(high)

R/W

3106h

Deceleration (1) time setting, 3rd
motor

F303 (low)

R/W

1 to 360000

0.01 [sec.]

3107h to

3202h

(Reserved) -

-

Inaccessible

-


(ix) List of registers (3rd control setting)

Register

No.

Function name

Function code

R/W

Monitoring and setting items Data resolution

Register

No.

3203h

Base frequency setting, 3rd
motor

A303

R/W 30 to "maximum frequency, 3rd motor"

1 [Hz]

3204h

Maximum frequency setting, 3rd
motor

A304

R/W 30 to 400

1 [Hz]

3205h to

3215h

(Reserved) -

-

Inaccessible

-

3216h A320

(high)

R/W

3217h

Multispeed frequency setting,
3rd motor

A320 (low)

R/W

0 or "start frequency" to "maximum frequency,
3rd motor"

0.01 [Hz]

3218h to

323Bh

(Reserved) -

-

Inaccessible

-

323Ch

Manual torque boost value, 3rd
motor

A342

R/W 0 to 200

0.1 [%]

323Dh

Manual torque boost frequency
adjustment, 3rd motor

A343

R/W 0 to 500

0.1 [%]

323Eh

V/F characteristic curve
selection, 3rd motor

A344

R/W 0 (VC), 1(VP)

-

323Fh to

326Ch

(Reserved) -

-

Inaccessible

-

326Dh A392

(high)

R/W

326Eh

Acceleration (2) time setting, 3rd
motor

A392 (low)

R/W

1 to 360000

0.01 [sec.]

326Fh A393

(high)

R/W

3270h

Deceleration (2) time setting, 3rd
motor

A393 (low)

R/W

1 to 360000

0.01 [sec.]

3271h to

330B

(Reserved) -

-

Inaccessible

-

330Ch

Electronic thermal setting
(calculated within the inverter
from current output), 3rd motor

b312

R/W 200 to 1000

0.1 [%]

330Dh

Electronic thermal characteristic,
3rd motor

b313 R/W

0 (reduced-torque characteristic), 1 (constant-
torque characteristic), 2 (free setting)

-

330Eh to

3506h

(Reserved) -

-

Inaccessible

-

3507h

Motor stabilization constant, 3rd
motor

H306

R/W 0 to 255

1

3508h to (Reserved)

-

-

Inaccessible

-

Advertising