Chapter 4 explanation of functions – Hitachi SJ700-2 User Manual

Page 133

Advertising
background image

Chapter 4 Explanation of Functions

4 -

70

4.2.75 Reverse rotation signal (RVR)

C021 to C025: Terminal [11] to [15] functions
C026: Alarm relay terminal function

Related code

The inverter continues to output the forward rotation (RVR)
signal while it is driving the motor for reverse operation.
The RVR signal is turned off while the inverter is driving the motor for forward operation or stopping the
motor.

Item

Function code

Data or range of data

Description

Terminal function

C021 to C025

Alarm relay terminal function

C026

52

RVR: Reverse rotation signal









4.2.76 Major failure signal (MJA)

Output f

Forwar

Reverse rot

requency (Hz)

d rotation signal

ation signal


C021 to C025: Terminal [11] to [15] functions
C026: Alarm relay terminal function

Related code

The inverter outputs the major failure (MJA) signal in addition to
an alarm signal when it trips because of one of the errors listed
below.
(This signal function applies to the tripping caused by hardware.)

No. Error

code

Description

1 E10.*

CT

error

2 E11.*

CPU

error

3 E14.*

Ground-fault

protection

4

E20.*

Temperature error due to cooling-fan fault

5

E23.*

Gate array communication error

6

E25.*

Main circuit error

Item

Function code

Data or range of data

Description

Terminal function

C021 to C025

Alarm relay terminal function

C026

53

MJA: Major failure signal

Advertising