Chapter 4 explanation of functions – Hitachi SJ700-2 User Manual

Page 205

Advertising
background image

Chapter 4 Explanation of Functions

4 - 142

(6) List of registers

The "R/W" column of the list indicates whether the coils and registers are read-only or readable and
writable.
"R" indicates a read-only coil or register. "R/W" indicates a readable and writable coil or register.

(i) List of coils

Coil No.

Item

R/W

Setting

0000h (Reserved)

-

0001h

Operation command

R/W

1: Run, 0: Stop (valid when A002 = 03)

0002h

Rotation direction command

R/W

1: Reverse rotation, 0: Forward rotation (valid when A002 = 03)

0003h

External trip (EXT)

R/W

1: Trip

0004h

Trip reset (RS)

R/W

1: Reset

0005h (Reserved)

-

0006h (Reserved)

-

0007h

Intelligent input terminal [1]

R/W

1: ON, 0: OFF (*1)

0008h

Intelligent input terminal [2]

R/W

1: ON, 0: OFF (*1)

0009h

Intelligent input terminal [3]

R/W

1: ON, 0: OFF (*1)

000Ah

Intelligent input terminal [4]

R/W

1: ON, 0: OFF (*1)

000Bh

Intelligent input terminal [5]

R/W

1: ON, 0: OFF (*1)

000Ch

Intelligent input terminal [6]

R/W

1: ON, 0: OFF (*1)

000Dh

Intelligent input terminal [7]

R/W

1: ON, 0: OFF (*1)

000Eh

Intelligent input terminal [8]

R/W

1: ON, 0: OFF (*1)

000Fh

Operation status

R

1: Run, 0: Stop (interlocked to "d003")

0010h

Rotation direction

R

1: Reverse rotation, 0: Forward rotation (interlocked to "d003")

0011h

Inverter ready

R

1: Ready, 0: Not ready

0012h Unused

R

0013h

RUN (running)

R

1: Tripping, 0: Normal

0014h

FA1 (constant-speed reached)

R

1: ON, 0: OFF

0015h

FA2 (set frequency overreached)

R

1: ON, 0: OFF

0016h

OL (overload notice advance signal (1))

R

1: ON, 0: OFF

0017h

OD (output deviation for PID control)

R

1: ON, 0: OFF

0018h

AL (alarm signal)

R

1: ON, 0: OFF

0019h

FA3 (set frequency reached)

R

1: ON, 0: OFF

001Ah

OTQ (over-torque)

R

1: ON, 0: OFF

001Bh

IP (instantaneous power failure)

R

1: ON, 0: OFF

001Ch

UV (undervoltage)

R

1: ON, 0: OFF

001Dh

TRQ (torque limited)

R

1: ON, 0: OFF

001Eh

RNT (operation time over)

R

1: ON, 0: OFF

001Fh

ONT (plug-in time over)

R

1: ON, 0: OFF

0020h

THM (thermal alarm signal)

R

1: ON, 0: OFF

0021h (Reserved)

-

0022h (Reserved)

-

0023h (Reserved)

-

0024h (Reserved)

-

0025h (Reserved)

-

0026h

BRK (brake release)

R

1: ON, 0: OFF

0027h

BER (brake error)

R

1: ON, 0: OFF

0028h

ZS (0 Hz detection signal)

R

1: ON, 0: OFF

0029h

DSE (speed deviation maximum)

R

1: ON, 0: OFF

002Ah

POK (positioning completed)

R

1: ON, 0: OFF

002Bh

FA4 (set frequency overreached 2)

R

1: ON, 0: OFF

002Ch

FA5 (set frequency reached 2)

R

1: ON, 0: OFF

002Dh

OL2 (overload notice advance signal
(2))

R

1: ON, 0: OFF

002Eh

Odc: Analog O disconnection detection

-

002Fh

OIDc: Analog OI disconnection
detection

-

0030h

O2Dc: Analog O2 disconnection
detection

-

0031h (Reserved)

-

0032h

FBV (PID feedback comparison)

R

1: ON, 0: OFF

0033h

NDc (communication train
disconnection)

R

1: ON, 0: OFF

0034h

LOG1 (logical operation result 1)

R

1: ON, 0: OFF