Chapter 4 explanation of functions – Hitachi SJ700-2 User Manual

Page 213

Advertising
background image

Chapter 4 Explanation of Functions

4 - 150

Register

No.

Function name

Function code

R/W

Monitoring and setting items Data resolution

Register

No.

125Fh

PID Function Enable

A071

R/W

0 (disabling), 1 (enabling), 2 (enabling inverted-data
output)

-

1260h

PID proportional gain

A072

R/W 2 to 50

0.1

1261h

PID integral time constant

A073

R/W 0 to 36000

0.1 [sec.]

1262h

PID derivative gain

A074

R/W 0 to 10000

0.01 [sec.]

1263h

PV scale conversion

A075

R/W 1 to 9999

0.01

1264h

PV source setting

A076

R/W

0 (input via OI), 1 (input via O), 2 (external
communication), 3 (pulse train frequency input), 10
(operation result output)

-

1265h

Reverse PID

A077

R/W 00 (disabling), 01 (enabling)

-

1266h

PID output limiter

A078

R/W 0 to 1000

0.1 [sec.]

1267h

PID feed forward selection

A079

R/W 0 (disabled), 1(O input), 2 (OI input), 3 (O2 input)

-

1268h (Reserved)

-

R/W

Inaccessible

-

1269h

AVR function select

A081

R/W

0 (always on), 1 (always off), 2 (off during
deceleration)

-

126Ah

AVR voltage select

A082

R/W

200 V class: 0 (200)/1 (215)/2 (220)/3 (230)/4 (240)
400 V class: 5 (380)/6 (400)/7 (415)/8 (440)/9 (460)/
10 (480)

-

126Bh (Reserved)

-

R/W Inaccessible

-

126Ch (Reserved)

-

R/W Inaccessible

-

126Dh Operation

mode

selection

A085

R/W

0 (normal operation), 1 (energy-saving operation), 2
(fuzzy operation)

-

126Eh

Energy saving mode
tuning

A086

R/W 0 to 1000

0.1 [%]

126Fh to

1273h

(Reserved) -

-

Inaccessible

-

1274h A092

(high)

R/W

1275h

Acceleration (2) time
setting

A092 (low)

R/W

1 to 360000

0.01 [sec.]

1276h A093

(high)

R/W

1277h

Deceleration (2) time
setting

A093 (low)

R/W

1 to 360000

0.01 [sec.]

1278h

Select method to switch to
Acc2/Dec2 profile

A094

R/W 0 (switching by 2CH terminal), 1 (switching by setting)

-

1279h A095

(high)

R/W

127Ah

Acc1 to Acc2 frequency
transition point

A095 (low)

R/W

0 to 40000

0.01 [Hz]

127Bh A096

(high)

R/W

127Ch

Dec1 to Dec2 frequency
transition point

A096 (low)

R/W

0 to 40000

0.01 [Hz]

127Dh

Acceleration curve
selection

A097 R/W

0 (linear), 1 (S curve), 2 (U curve), 3 (inverted-U
curve), 4 (EL-S curve)

-

127Eh

Deceleration curve setting

A098

R/W

0 (linear), 1 (S curve), 2 (U curve), 3 (inverted-U
curve), 4 (EL-S curve)

-

127Fh (Reserved)

-

- Inaccessible

-

1280h (Reserved)

-

- Inaccessible

-

1281h A101

(high)

R/W

1282h

[OI]-[L] input active range
start frequency

A101 (low)

R/W

0 to 40000

0.01 [Hz]

1283h A102

(high)

R/W

1284h

[OI]-[L] input active range
end frequency

A102 (low)

R/W

0 to 40000

0.01 [Hz]

1285h

[OI]-[L] input active range
start current

A103

R/W 0 to "[OI]-[L] input active range end current"

1 [%]

1286h

[OI]-[L] input active range
end current

A104

R/W "[OI]-[L] input active range start current" to 100

1 [%]

1287h

[OI]-[L] input start
frequency enable

A105

R/W 0 (external start frequency), 1 (0 Hz)

-

1288h to

128Ch

(Reserved) -

-

Inaccessible

-

128Dh A111

(high)

R/W

128Eh

[O2]-[L] input active range
start frequency

A111 (low)

R/W

-40000 to 40000

0.01 [Hz]

128Fh A112

(high)

R/W

1290h

[O2]-[L] input active range
end frequency

A112 (low)

R/W

-40000 to 40000

0.01 [Hz]

1291h

[O2]-[L] input active range
start voltage

A113

R/W -100 to "[O2]-[L] input active range end voltage"

1 [%]

1292h

[O2]-[L] input active range
end voltage

A114

R/W "[O2]-[L] input active range start voltage" to 100

1 [%]

1293h to

12A4h

(Reserved) -

-

Inaccessible

-

12A5h

Acceleration curve
constants setting

A131

R/W 1 (smallest swelling) to 10 (largest swelling)

-

12A6h

Deceleration curve
constants setting

A132

R/W 1 (smallest swelling) to 10 (largest swelling)

-

12A7h to

12AEh

(Reserved) -

-

Inaccessible

-

12AFh Operation-target frequency

A141

R/W 0 (digital operator), 1 (keypad potentiometer), 2 (input

-

Advertising