Chapter 4 explanation of functions – Hitachi SJ700-2 User Manual

Page 187

Advertising
background image

Chapter 4 Explanation of Functions

4 - 12

4

(v) 04 command: This command reads the status of the inverter.
- Transmission frame
Frame format

STX Station

No.

Command BCC

CR

Description

Data

size

Setting

STX

Control code (Start of TeXt)

1 byte

STX (0x02)

Station No.

Station number of control-target
inverter

2 bytes

01 to 32

Command

Command to be transmitted

2 bytes

04

BCC

Block check code

2 bytes

XOR of the items from "Station No." to "Data."
See Item (3) of this section.

CR

Control code (Carriage Return)

1 byte

CR (0x0D)


- Response frame
Frame format

STX Station

No. Data

BCC

CR

Description

Data

size

Setting

STX

Control code (Start of TeXt)

1 byte

STX (0x02)

Station No.

Station number of control-target
inverter

2 bytes

01 to 32

Data

Data

8 bytes

See Note 8.

BCC

Block check code

2 bytes

XOR of the items from "Station No." to "Data."
See Item (3) of this section.

CR

Control code (Carriage Return)

1 byte

CR (0x0D)


Note 10:

The data indicating the status of the inverter consists of the following three status

elements (A, B, and C):

Data

Status A

Status B

Status C

00 (reserved)


Inverter status A

Inverter status B

Inverter status C

Code Status

Code

Status

Code

Status

00 Initial

status

00 Stopping

00

---

01

01

Running

01

Stopping

02 Stopping

02

Tripping

02

Decelerating

03 Running

03

Constant-speed

operation

04

Free-run stop (FRS) in progress

04

Accelerating

05

Jogging (JG) in progress

05

Forward operation

06

DC braking (DB) in progress

06

Reverse operation

07

Retry in progress

07

Switching forward operation

08

Tripping

to reverse operation

09

Undervoltage (UV) status

08

Switching reverse operation

to forward operation

09 Starting

forward

operation

10

Starting

reverse

operation

Advertising