Chapter 4 explanation of functions – Hitachi SJ700-2 User Manual

Page 142

Advertising
background image

Chapter 4 Explanation of Functions

4 -

79

4.2.86 Automatic user-parameter setting

The automatic user-parameter setting function allows you to make the
inverter automatically store the parameters you readjusted sequentially
as user parameters "U001" to "U012". You can use the stored data as a
readjustment history. To enable this function, select "01" (enabling
automatic user-parameter setting) for the automatic user-parameter
setting function enable (b039).
The setting data entered in (displayed on) the digital operator is stored when the STR key is pressed. Also
the monitor screen code (d***) is stored at the same time.
User parameter "U001" retains the latest update of setting; user parameter "U012", the oldest update.
A functional parameter can be stored as only a single user parameter. After all the 12 user parameters
have been used to store functional-parameter settings, new functional-parameter settings will be stored as
user parameters on a first-in, first-out basis (that is, the next parameter will be written to "U012", storing the
oldest update, first).

Item Function

code

Data Description

00

Disabling automatic user

Automatic user-parameter setting
function enable

b039

01

Enabling automatic user

4.2.87 Stabilization constant setting

The stabilization constant setting function allows you to adjust the inverter
to stabilize the motor operation when the motor operation is unstable.
If the motor operation is unstable, check the motor capacity setting (H003/H203) and motor pole setting
(H004/H204) to determine whether the settings match the motor specifications. If they do not match,
readjust the settings. If the primary resistance of the motor is less than the standard motor specification, try
to increase the setting of "H006/H206/H306" step by step. Try to reduce the setting of "H006/H206/H306" if
the inverter is driving a motor of which the capacity is higher than the inverter rating.
You can also use the following methods to stabilize the motor operation:
1) Reducing the carrier frequency (b083) (See Section 4.2.11.)
2) Reducing the V/f gain setting (A045) (See Section 4.2.17.)

Item Function

code

Data

Description

Stabilization constant

H006/H206/

H306

0. to 255.

Increase or reduce the setting to stabilize
the motor.

V/f gain setting

A045

20. to 100. (%)

Reduce the setting to stabilize the motor.

Carrier frequency setting

b083

0.5 to 15.0 (kHz)

Reduce the setting to stabilize the motor.

4.2.88 Selection of operation at option board error

Data

You can select how the inverter operates when an error results from
a built-in option board between two modes. In one mode, the
inverter trips. In the other mode, the inverter ignores the error and
continues the operation.
When you use the feedback option board (SJ-FB) as option board 1,
specify "01" for "P001". When you use the SJ-FB as option board 2,
specify "01" for "P002".

Item Function

code

Description

00 TRP:

Alarm

output

Operation mode on
expansion card 1 and 2
errors

P001/P002

01

RUN: Continuation of operation

b039: Automatic user-parameter
setting function enable
U001 to U012: User parameters

Related code

H006/H206/H306: Motor stabilization

constant, 1st/2nd/3rd motors
A045: V/f gain setting
b083: Carrier frequency setting

Related code

P001: Operation mode on expansion card 1
error
P002: Operation mode on expansion card 2
error