Chapter 5 error codes – Hitachi SJ700-2 User Manual

Page 237

Advertising
background image

Chapter 5 Error Codes

5.1.2 Option boards error codes

When an option board is mounted in the optional port 1 (located near the operator connector), the error

code display format is "E6*. " (on the digital operator) or "OP1-*" (on the remote operator). When it is

mounted in the optional port 2 (located near the control circuit terminal block), the error code display

format is "E7*. " (on the digital operator) or "OP2-*" (on the remote operator).

1) Error indications by protective functions with the feedback option board (SJ-FB) mounted

Name Description

Display on digital

operator

Display on

remote operator

ERR1***

Encoder

disconnection

If the encoder wiring is disconnected, an encoder
connection error is detected, the encoder fails, or an
encoder that does not support line driver output is
used, the inverter will shut off its output and display
the error code shown on the right.

OP1-0

OP2-0

Excessive speed

If the motor speed rises to "maximum frequency
(A004) x over-speed error detection level (P026)" or
more, the inverter will shut off its output and display
the error code shown on the right.

OP1-1

OP2-1

Positioning error

If, in position control mode, the deviation of the
current position from that specified by the
positioning command increases to 1,000,000 pulses
or more, the inverter will shut off its output and
display the error code shown on the right.

OP1-2

OP2-2

Position control

range trip

In absolute position control mode, the inverter shuts
off its output and indicates an error when the range
specified by the position range specification
(forward) (P072) or position range specification
(reverse) (P073) is exceeded.

OP1-3

OP2-3

SJ-FB connection

error

If a faulty connection (i.e., mounting) of the
feedback option board is detected, the inverter will
shut off its output and display the error code shown
on the right.

OP1-9

OP2-9

Note: If the option board does not operate normally, confirm the DIP switch settings on the option board.

Functions of the DIP switches on the feedback option board (SJ-FB)

DIP switch

Switch No.

Setting

ON

Enabling the detection of encoder disconnection when the encoder
phases A and B are not connected

1

OFF

Disabling the detection of encoder disconnection when the encoder
phases A and B are not connected

ON

Enabling the detection of encoder disconnection when the encoder
phase Z is not connected

SWENC

2

OFF

Disabling the detection of encoder disconnection when the encoder
phase Z is not connected

ON

Enabling the terminating resistor between the SAP and SAN terminals
(150

Ω)

1

OFF

Disabling the terminating resistor between the SAP and SAN terminals

ON

Enabling the terminating resistor between the SBP and SBN terminals
(150

Ω)

SWR

2

OFF

Disabling the terminating resistor between the SBP and SBN terminals

Note: For details, refer to the instruction manual for the option board.