Chapter 7 specifications, 1 specifications, 1) specifications of the 200 v class model – Hitachi SJ700-2 User Manual

Page 253: 2) specifications of the 400 v class model

Advertising
background image

Chapter 7 Specifications

7 - 1

7.1 Specifications

(1) Specifications of the 200 V class model

Model name (type name)

SJ700-XXXLFF,LFU

055 075 110 150 185 220 300 370 450 550

Max. applicable motor
capacity (4-pole) (kW)

5.5 7.5 11 15 18.5 22 30 37 45 55

200V

8.3 11.0 15.9 22.1 26.3 32.9 41.9 50.2 63.0 76.2

Rated capacity

(kVA)

240V

9.9 13.3 19.1 26.6 31.5 39.4 50.2 60.2 75.6 91.4

Rated input AC voltage

Three-phase (3-wire), 200 to 240 V (+10%, -15%), 50/60 Hz (±5%)

Rated output voltage

Three-phase (3-wire), 200 to 240 V (corresponding to the input voltage)

Rated output current (A)

24 32 46 64 76 95 121

145

182

220

Regenerative braking

Internal BRD circuit (external discharge resistor)

External regenerative braking unit

B

ra

k

-

ing Minimum connectable

resistance (

Ω)

17 17 17 7.5 7.5 5

-

Approx. weight (kg)

6 6 6 14

14

14

22

30

30

43


(2)

Specifications of the 400 V class model

Model name (type name)

SJ700-XXXXHFF,HFEF,HFUF

055 075 110 150 185 220 300 370 450 550

Max. applicable motor
capacity (4-pole) (kW)

5.5 7.5 11 15 18.5

22 30 37 45 55

400V

9.7 13.1 17.3 22.1 26.3 33.2 40.1 51.9 63.0 77.6

Rated capacity
(kVA)

480V

11.6 15.8 20.7 26.6 31.5 39.9 48.2 62.3 75.6 93.1

Rated input AC voltage

Three-phase (3-wire), 380 to 480 V (+10%, -15%), 50/60 Hz (±5%)

Rated output voltage

Three-phase (3-wire), 380 to 480 V (corresponding to the input voltage)

Rated output current (A)

14 19 25 32 38 48 58 75 91 112

Regenerative braking

Internal BRD circuit (external discharge resistor)

External regenerative braking unit

B

ra

k

-

in

g

Minimum connectable

resistance (

Ω)

70 50 50 24 24 20

-

Approx.

weight

(kg) 6 6 6 14

14

14

22 30

30

30


(3) Common specifications of 200 V class and 400 V class models

Model name (type name)

SJ700-XXXXXFF,FEF,FUF

055

L/H

075

L/H

110
L/H

150

L/H

185

L/H

220

L/H

300

L/H

370

L/H

450

L/H

550

L/H

Protective structure

IP20

Control system

Sine-wave PWM control

Output frequency range

0.1 to 400 Hz

Frequency accuracy

Within ±0.01% of the maximum output frequency for digital input, within ±0.2% of maximum frequency
for digital input (at 25±10

°C)

Frequency setting
resolution

Digital input: 0.01 Hz
Analog input: Maximum output frequency/4000
(O terminal input: 12 bits/0 to +10 V, O2 terminal input: 12 bits/-10 to +10 V, OI terminal input: 12 bits/0
to +20 mA)

Voltage/frequency
characteristic

V/f characteristic variable with the base frequency set between 30 to 400 Hz, constant- or
reduced-torque V/f control, sensorless vector control, 0Hz-range sensorless vector control

Speed fluctuation

±0.5% (with sensorless vector control or 0Hz-range sensorless vector control)

Rated overload current

150%/60 seconds, 200%/3 seconds

Acceleration/deceleration
time

0.01 to 3,600.0 seconds (in linear or curved pattern)

200%/0.3 Hz (with sensorless vector control or 0Hz-range sensorless vector control)

Starting torque

150%/0Hz-range torque (with 0Hz-range sensorless vector control or with a motor of capacity one
class lower than the inverter connected)

DC braking

Triggered at motor start-up, when the actual motor frequency exceeds the acceleration frequency set
by a stop command, when the actual motor frequency exceeds the frequency set by a frequency
command, or by an externally input command (braking force, time, and frequency are variable).

Advertising