Chapter 8 list of data settings – Hitachi SJ700-2 User Manual

Page 273

Advertising
background image

Chapter 8 List of Data Settings

8 - 13

Default

Code

Function name

Monitored data or setting

_FF _FEF

_FUF

Setting

during

operation

(allowed or

not)

Change

during

operation

(allowed or

not)

Page

H001 Auto-tuning

Setting

00 (disabling auto-tuning), 01 (auto-tuning without rotation), 02 (auto-tuning
with rotation)

00

¯

¯

H002

Motor data selection, 1st motor

00 (Hitachi standard data), 01 (auto-tuned data),
02 (auto-tuned data [with online auto-tuning function])

00

¯

¯

H202

Motor data selection, 2nd motor

00 (Hitachi standard data), 01 (auto-tuned data),
02 (auto-tuned data [with online auto-tuning function])

00

¯

¯

H003

Motor capacity, 1st motor

0.20 to 75.00 (kW)

Factory setting

¯

¯

H203

Motor capacity, 2nd motor

0.20 to 75.00 (kW)

Factory setting

¯

¯

H004

Motor poles setting, 1st motor

2, 4, 6, 8, 10 (poles)

4

¯

¯

H204

Motor poles setting, 2nd motor

2, 4, 6, 8, 10 (poles)

4

¯

¯

4-85

H005

Motor speed constant, 1st motor

0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)

1.590

{

{

H205

Motor speed constant, 2nd motor

0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)

1.590

{

{

4-89

H006

Motor stabilization constant, 1st
motor

0. to 255.

100.

{

{

H206

Motor stabilization constant, 2nd
motor

0. to 255.

100.

{

{

H306

Motor stabilization constant, 3rd
motor

0. to 255.

100.

{

{

4-79

H020

Motor constant R1, 1st motor

0.001 to 9.999, 10.00 to 65.53 (

Ω)

Depending on motor capacity

¯

¯

H220

Motor constant R1, 2nd motor

0.001 to 9.999, 10.00 to 65.53 (

Ω)

Depending on motor capacity

¯

¯

H221

Motor constant R2, 1st motor

0.001 to 9.999, 10.00 to 65.53 (

Ω)

Depending on motor capacity

¯

¯

H221

Motor constant R2, 2nd motor

0.001 to 9.999, 10.00 to 65.53 (

Ω)

Depending on motor capacity

¯

¯

H222

Motor constant L, 1st motor

0.01 to 99.99, 100.0 to 655.3 (mH)

Depending on motor capacity

¯

¯

H222

Motor constant L, 2nd motor

0.01 to 99.99, 100.0 to 655.3 (mH)

Depending on motor capacity

¯

¯

H223

Motor constant Io

0.01 to 99.99, 100.0 to 655.3 (A)

Depending on motor capacity

¯

¯

H223

Motor constant Io, 2nd motor

0.01 to 99.99, 100.0 to 655.3 (A)

Depending on motor capacity

¯

¯

H224

Motor constant J

0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.

Depending on motor capacity

¯

¯

H224

Motor constant J, 2nd motor

0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.

Depending on motor capacity

¯

¯

4-88

H030

Auto constant R1, 1st motor

0.001 to 9.999, 10.00 to 65.53 (

Ω)

Depending on motor capacity

¯

¯

H230

Auto constant R1, 2nd motor

0.001 to 9.999, 10.00 to 65.53 (

Ω)

Depending on motor capacity

¯

¯

H231

Auto constant R2, 1st motor

0.001 to 9.999, 10.00 to 65.53 (

Ω)

Depending on motor capacity

¯

¯

H231

Auto constant R2, 2nd motor

0.001 to 9.999, 10.00 to 65.53 (

Ω)

Depending on motor capacity

¯

¯

H232

Auto constant L, 1st motor

0.01 to 99.99, 100.0 to 655.3 (mH)

Depending on motor capacity

¯

¯

H232

Auto constant L, 2nd motor

0.01 to 99.99, 100.0 to 655.3 (mH)

Depending on motor capacity

¯

¯

H233

Auto constant Io, 1st motor

0.01 to 99.99, 100.0 to 655.3 (A)

Depending on motor capacity

¯

¯

H233

Auto constant Io, 2nd motor

0.01 to 99.99, 100.0 to 655.3 (A)

Depending on motor capacity

¯

¯

H234

Auto constant J, 1st motor

0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.

Depending on motor capacity

¯

¯

Cont

ro

l cons

tan

ts

H234

Auto constant J, 2nd motor

0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.

Depending on motor capacity

¯

¯

4-85

Advertising