Chapter 4 Explanation of Functions

4 -

77

No.

Display condition

Parameter displayed when the display condition is met

27

One of C001 to C008 = 05 and A019 = 00

A028 to A035

28

One of C001 to C008 = 06

A038 and A039

29

One of C001 to C008 = 07

A053 to A055 and A059

30

One of C001 to C008 = 08

F202, F203, A203, A204, A220, A244, A246, A247, A261,
A262, A292, A293, A294, b212, B213, H203, H204 and
H206

31

One of C001 to C008 = 08 and A041 = 01

A246 and A247

32

One of C001 to C008 = 08 and A244 = 00 or
01

A241, A242 and A243

33

One of C001 to C008 = 08 and A244 = 03 or
04

H202, H205, H250, H251 and H252

34

One of C001 to C008 = 08 and A244 = 04

H260 and H261

35

One of C001 to C008 = 08, A244 = 03 or 04,
and H202 = 00

H220 to H224

36

One of C001 to C008 = 08, A244 = 03 or 04,
and H202 = 01 or 02

H230 to H234

37

One of C001 to C008 = 08 and A094 = 01 or
02

A295 and A296

38

One of C001 to C008 = 11

b088

39

One of C001 to C008 = 17

F302, F303, A303, A304, A320, A342, A343, A392, A393,
b312, b313 and H306

40

One of C001 to C008 = 18

C102

41

One of C001 to C008 = 27, 28, or 29

C101

42

One of C021 to C008 = 03

C040 and C041

43

One of C021 to C008 = 26

C040 and C111

44

One of C021 to C008 = 02 or 06

C042 and C043

45

One of C021 to C008 = 07

C055 to C058

46

One of C021 to C008 = 21

C063

47

One of C021 to C008 = 24 or 25

C045 and C046

48

One of C021 to C008 = 33

C142 to C144

49

One of C021 to C008 = 34

C145 to C147

50

One of C021 to C008 = 35

C148 to C150

51

One of C021 to C008 = 36

C151 to C153

52

One of C021 to C008 = 37

C154 to C156

53

One of C021 to C008 = 38

C157 to C159

54

One of C021 to C008 = 42

C064


(2) User-setting display mode
The monitor displays only the codes and items that are arbitrarily assigned to user parameters (U001 to
U012), except codes "d001", "F001", and "b037".

(3) Data comparison display mode
The monitor displays only the parameters that have been changed from the factory settings, except all
monitoring indications (d***) and code "F001".
Note that the settings of input span calibration and input zero calibration (C081 to C083 and C121 to C123),
and thermistor input tuning (C085) are not always displayed.

Advertising