Chapter 4 explanation of functions, 4 torque biasing function, 5 torque control function – Hitachi SJ700-2 User Manual

Page 163

Advertising
background image

Chapter 4 Explanation of Functions

4.3.4 Torque biasing function

The torque biasing function allows you to make the inverter bias the
torque command generated during the operation in speed control
mode. You can effectively use this function for inverter applications to a
lift or other elevating machines.

P036: Torque biasing mode selection
P037: Torque bias setting
P038: Torque biasing polarity selection
d010: Torque bias monitoring

Related code

Item

Function code

Data or range of data

Description

00 None
01

Bias setting from the digital operator

Torque biasing mode
selection

P036

02

Bias setting via the O2 terminal (*1)

Torque bias setting

P037

-200 to +200 (%)

Valid when "P036" = "01"

00

Depending on the sign of bias value

Torque biasing polarity
selection (*2)

P038

01

Depending on the motor rotation direction

*1 When the torque bias is set as a signal input via the O2 terminal, the inverter recognizes the signal

voltage -10 to +10 (V) as the bias value -200 to +200 (%).

*2 1) When "00" (depending on the sign of the bias value) is specified:

Regardless of the direction of motor rotation, torque in the forward direction increases when the
torque bias signal indicates a positive (+) value. Torque in the reverse direction increases when
the torque bias signal indicates a negative (-) value.

2) When "01" (depending on the motor rotation direction) is specified:

The sign of the bias value indicated by the torque bias signal and the direction of the torque
biasing change according to the rotation direction specified by the operation command.

With a forward operation command: the torque is generated in the same direction as that
specified by the sign of the torque bias value.

With a reverse operation command: the torque is generated in the opposite direction to that
specified by the sign of the torque bias value.

4.3.5 Torque control function

P033: Torque command input selection
P034: Torque command setting
P035: Polarity selection at the torque
command input via the O2 terminal
P039: Speed limit for torque-controlled
operation (forward rotation)
P040: Speed limit for torque-controlled
operation (reverse rotation)
d009/d010/d012: Torque command monitoring
P036: Torque biasing mode selection
P037: Torque bias setting
P038: Torque biasing polarity selection
d010: Torque bias monitoring
C001 to C008: Terminal [1] to [8] functions

Related code

The torque control function is effective in the V2 control mode.
You can use the inverter not only under the speed control or
pulse train position control but also with this torque control
function. You can use this function effectively for inverter
applications to, for example, a winding machine.
To operate the inverter to drive the motor under torque control,
assign function "52" (ATR) to an intelligent input terminal. The
torque command input is enabled when the ATR terminal is on.
You can select one of four torque command input methods
(digital operator and three analog input terminals) by the torque
command input selection (P034).

Item

Function code

Data or range of data

Description

00

Input from the O terminal

01

Input from the OI terminal

02

Input from the O2 terminal

Torque command input
selection

P033

03

Input from the digital operator

Torque command setting

P034

0 to 200 (%)

Torque setting for the input from the digital
operator (P033 = 03)

00

Depending on the sign of torque value

Polarity selection at the torque
command input via the O2
terminal

P035

01

Depending on the motor rotation direction

Speed limit for torque-
controlled operation (forward
rotation)

P039

0.00 to 99.99 or 100.0 to

400.0 (Hz)

Speed limit for torque-
controlled operation (reverse
rotation)

P040

0.00 to 99.99 or 100.0 to

400.0 (Hz)

00 None

01

Bias setting from the digital operator

Torque biasing mode selection

P036

02

Bias setting via the O2 terminal

Torque bias setting

P037

-200 to +200 (%)

Valid when "P036" = "01"

00

Depending on the sign of bias value

Torque biasing polarity
selection

P038

01

Depending on the motor rotation direction

Terminal function

C001 to C008

52

ATR: Permission for torque command input

4 - 10

0

Advertising