Chapter 2 Installation and Wiring

(4) Connecting a programmable controller to intelligent input terminals

When using the internal interface power supply

When using an external power supply

(Remove the jumper from the control circuit terminal block.)

Sink logi

c

Source logi

c

Inverter

PLC

8

COM

YTR48 type
output module

S

DC24V

FW

CM1

DC24V

P24

Inverter

YTR48 type
output module

Jumper

S

COM

P24

PLC

CM1

FW

8

DC24V

Inverter

YTS48 type
output module

DC24V

DC24V

COM

S

P24

PLC
CM1

8

FW

DC24V

Inverter

YTS48 type
output module

S

COM

P24

PLC

CM1

FW

8

Jumper

(5) Connecting a programmable controller to intelligent output terminals

Sink logi

c

Source logi

c

XDC24D2H

Inverter

11

12

CM2

COM

DC24V

DC24V

COM

CM2

12

XDC24D2H

11

Inverter

2.2.4 Wiring of the digital operator

- You can operate the inverter with not only the digital operator mounted in the inverter as standard

equipment but also an optional digital operator (OPE-S, OPE-SR, SRW-OJ, or SRW-OEX).

- When you intend to remove the standard digital operator from the inverter and use it as remote

equipment, request your local Hitachi Distributor to supply a connection cable, ICS-1 (1-meter cable) or
ICS-3 (3-meter cable).

If you prepare the cable by yourself, the following product is recommended:
HUTP5 PC 4P -X-X: Straight cable equipped with connector at both ends (made by Hitachi Cable, Ltd.)
- The length of the connection cable must be 3 m or less. If a cable over 3 m is used, the inverter may

malfunction.