Chapter 4 Explanation of Functions

(2) Start/end frequency settings for the O2-L terminal

Item

Function code

Range of data

Description

Remarks

02 start frequency

A111

-400. to 400.(Hz)

Setting of the start frequency

02 end frequency

A112

-400. to 400.(Hz)

Setting of the end frequency

02 start-frequency
rate

A113

-100. to 100.(%)

Setting of the rate of the start frequency
to the external frequency command (-10
to +10 V) (*1)

02 end-frequency
rate

A114

-100. to 100.(%)

Setting of the rate of the end frequency
to the external frequency command (-10
to +10 V) (*1)

(Example 3)

(Example 3)

A111

A114

A113

A112

(-10V)
-100%

(+10V)

100%

Maximum frequency for
forward operation

Analog input
(O2)

Maximum frequency for
reverse operation

*1 The frequency rates correspond to the voltages

(-10 to +10 V) of the external frequency command
as follows:

-10 to 0 V: -100% to 0%

0 to +10 V: 0% to 100%

For example, if the voltage of the signal to be input to
the O2-L terminal is -5 to +5 V, specify 50% for "A114".



4.2.15 External analog input (O/OI/O2) filter setting

4 - 1

5

A016: External frequency filter time
const.

Related code

The external analog input filter setting function allows you to set the
input-voltage/input-current sampling time to be applied when frequency
commands are input as external analog signals.
You can use this filter function effectively for removing noise from the frequency-setting circuit signal.
If the noise disables the stable operation of the inverter, increase the setting. Setting a larger value makes
the inverter response slower. The filtering constant is "set value (1 to 30) x 2 ms."
When the setting is "31" (factory setting), a hysteresis of ±0.1 Hz is added to the filtering constant (500
ms).

Item

Function code

Range of data

Description

External frequency filter
time const.

A016

1. to 30. or 31.

Setting of 1. to 30.: "Set value x 2" ms filter
Setting of 31.: 500 ms filter (fixed) with hysteresis
of ±0.1 Hz

4.2.16 V/f gain setting

A045: V/f gain setting
A082: AVR voltage select

Related code

The V/f gain setting function allows you to change the inverter output
voltage by specifying the rate of the output voltage to the voltage (100%)
selected with the AVR voltage select function (A082).
If the motor operation is cranky, try to increase the gain setting.

Item

Function code

Range of data

Description

V/f gain setting

A045

20. to 100. (%)

Setting of the rate of reducing the output voltage

A045

AVR voltage
select
(100%)

Base
frequency

Maximum
frequency