Chapter 8 List of Data Settings

8 - 3

8.4 Extended Function Mode

Default

Code

Function name

Monitored data or setting

_FF

_FEF

_FUF

Setting

during

operation

(allowed or

not)

Change

during

operation

(allowed or

not)

Page

A001

Frequency source setting

00 (keypad potentiometer) (*1), 01 (control circuit terminal block), 02 (digital
operator), 03 (RS485), 04 (option 1), 05 (option 2), 06 (pulse-string input), 07
(easy sequence), 10 (operation function result)

02 01 01 ¯

¯

4-8

A002

Run command source setting

01 (control circuit terminal block), 02 (digital operator), 03 (RS485), 04 (option
1), 05 (option 2)

02 01 01 ¯

¯

4-8

A003

Base frequency setting

30. to "maximum frequency " (Hz)

60.

50.

60.

¯

¯

A203

Base frequency setting, 2nd
motor

30. to "maximum frequency, 2nd motor" (Hz)

60. 50. 60. ¯

¯

A303

Base frequency setting, 3rd
motor

30. to "maximum frequency, 3rd motor" (Hz)

60. 50. 60. ¯

¯

4-11

A004

Maximum frequency setting

30. to 400. (Hz)

60.

50.

60.

¯

¯

A204

Maximum frequency setting, 2nd
motor

30. to 400. (Hz)

60. 50. 60. ¯

¯

Basic set

tings

A304

Maximum frequency setting, 3rd
motor

30. to 400. (Hz)

60. 50. 60. ¯

¯

4-11

A005

[AT] selection

00 (switching between O and OI terminals), 01 (switching between O and O2
terminals), 02 (switching between O terminal and keypad potentiometer) (*1),
03 (switching between OI terminal and keypad potentiometer) (*1), 04
(switching between O2 and keypad potentiometer) (*1)

00

¯

¯

A006

[O2] selection

00 (single), 01 (auxiliary frequency input via O and OI terminals)
(nonreversible), 02 (auxiliary frequency input via O and OI terminals)
(reversible), 03 (disabling O2 terminal)

03

¯

¯

4-12

A011

[O]-[L] input active range start
frequency

0.00 to 99.99, 100.0 to 400.0 (Hz)

0.00

¯

{

A012

[O]-[L] input active range end
frequency

0.00 to 99.99, 100.0 to 400.0 (Hz)

0.00

¯

{

A013

[O]-[L] input active range start
voltage

0. to "[O]-[L] input active range end voltage" (%)

0.

¯

{

A014

[O]-[L] input active range end
voltage

"[O]-[L] input active range start voltage" to 100. (%)

100.

¯

{

A015

[O]-[L] input active range start
frequency selection

00 (external start frequency), 01 (0 Hz)

01

¯

{

4-14

A016

External frequency filter time
const.

1. to 30. or 31. (500 ms filter ±0.1 Hz with hysteresis)

31.

¯

{

4-15

Analog input

and o

the

rs

A017

Easy sequence function
selection

00 (disabling), 01 (enabling)

00

¯

¯

4-95

A019

Multispeed operation selection

00 (binary: 16 speeds selectable with 4 terminals), 01 (bit: 8 speeds selectable
with 7 terminals)

00

¯

¯

A020

Multispeed frequency setting

0.0 or “start frequency” to “maximum frequency” (Hz)

0.00

{

{

A220

Multispeed frequency setting,
2nd motor

0.0 or “start frequency” to “maximum frequency, 2nd motor” (Hz)

0.00

{

{

A320

Multispeed frequency setting,
3rd motor

0.0 or “start frequency” to “maximum frequency, 3rd motor” (Hz)

0.00

{

{

A021

Multispeed 1 setting

0.0 or “start frequency” to “1st maximum frequency” (Hz)

0.00

{

{

A022

Multispeed 2 setting

0.0 or “start frequency” to “2nd maximum frequency” (Hz)

0.00

{

{

A023

Multispeed 3 setting

0.0 or “start frequency” to “3rd maximum frequency” (Hz)

0.00

{

{

A024

Multispeed 4 setting

0.0 or “start frequency” to “n-th maximum frequency” (Hz)

0.00

{

{

A025

Multispeed 5 setting

0.0 or “start frequency” to “n-th maximum frequency” (Hz)

0.00

{

{

A026

Multispeed 6 setting

0.0 or “start frequency” to “n-th maximum frequency” (Hz)

0.00

{

{

A027

Multispeed 7 setting

0.0 or “start frequency” to “n-th maximum frequency” (Hz)

0.00

{

{

A028

Multispeed 8 setting

0.0 or “start frequency” to “n-th maximum frequency” (Hz)

0.00

{

{

A029

Multispeed 9 setting

0.0 or “start frequency” to “n-th maximum frequency” (Hz)

0.00

{

{

A030

Multispeed 10 setting

0.0 or “start frequency” to “n-th maximum frequency” (Hz)

0.00

{

{

A031

Multispeed 11 setting

0.0 or “start frequency” to “n-th maximum frequency” (Hz)

0.00

{

{

A032

Multispeed 12 setting

0.0 or “start frequency” to “n-th maximum frequency” (Hz)

0.00

{

{

A033

Multispeed 13 setting

0.0 or “start frequency” to “n-th maximum frequency” (Hz)

0.00

{

{

A034

Multispeed 14 setting

0.0 or “start frequency” to “n-th maximum frequency” (Hz)

0.00

{

{

A035

Multispeed 15 setting

0.0 or “start frequency” to “n-th maximum frequency” (Hz)

0.00

{

{

4-47

A038

Jog frequency setting

"Start frequency" to 9.99 (Hz)

1.00

{

{

M

ult

ispeed ope

rat

ion

an

d jogging

A039 Jog

stop

mode

00 (free-running after jogging stops [disabled during operation]), 01
(deceleration and stop after jogging stops [disabled during operation]), 02 (DC
braking after jogging stops [disabled during operation]), 03 (free-running after
jogging stops [enabled during operation]), 04 (deceleration and stop after
jogging stops [enabled during operation]), 05 (DC braking after jogging stops
[enabled during operation])

00

¯

{

4-49

*1 This setting is valid only when the OPE-SR is connected.