Chapter 4 explanation of functions, 25 acceleration/deceleration curve selection – Hitachi SJ700-2 User Manual

Page 94

Advertising
background image

Chapter 4 Explanation of Functions

4.2.25 Acceleration/deceleration curve selection

Related code

A097: Acceleration curve selection

A098: Deceleration curve setting

A131: Acceleration curve constants setting

A132: Deceleration curve constants setting

A150: Curvature for EL-S-curve acceleration 1

A151: Curvature for EL-S-curve acceleration 2

A152: Curvature for EL-S-curve deceleration 1

A153: Curvature for EL-S-curve deceleration 2

You can set different patterns of motor acceleration and
deceleration according to the type of system to be driven by the
inverter.
Use functions "A097" and "A098" to select acceleration and
deceleration patterns, respectively.
You can individually set an acceleration pattern for acceleration and a deceleration pattern for
deceleration.
When the acceleration/deceleration pattern is set other than 00 (linear) using analog input as frequency
source is to be avoided because it prolongs the acceleration or deceleration time.

Item

Function code

Data or range of data

Description

00 Linear

acceleration/deceleration

01 S-curve

acceleration/deceleration

02 U-curve

acceleration/deceleration

03 Inverted-U-curve

acceleration/deceleration

Acceleration/deceleration
curve selection

A097/A098

04 EL-S-curve

acceleration/deceleration

Acceleration/deceleration
curve constants setting

A131/ A132

01 to 10

01 (small degree of swelling)


10 (large degree of swelling)

Curvature for EL-S-curve
acceleration 1/2

A150/A151

0 to 50 (%)

Curvature of EL-S curve (for acceleration)

Curvature for EL-S-curve
deceleration 1/2

A152/A153

0 to 50 (%)

Curvature of EL-S curve (for deceleration)


(1) Acceleration/deceleration pattern selection

Select acceleration and deceleration patterns with reference to the following table:

Setting

00 01 02 03 04

Curve

Linear

S curve

U curve

Inverted-U curve

EL-S curve


A097

(accele-

ration

pattern)


A098

(decele-

ration

pattern)

Descrip-

tion

With this pattern, the
motor is accelerated or
decelerated linearly
until its speed reaches
the set output
frequency.

This pattern is
effective for preventing
the collapse of cargo
carried by a lift or
conveyor driven by the
inverter.

This pattern is effective for the tension control
on a winding machine driven by the inverter (to
prevent cutting of the object to be wound).

This pattern is similar
to the S-curve pattern
for the shockless
starting and stopping
of the motor, except
that the middle
section of this pattern
is linear.

Outpu

t frequ

ency

Time

Outpu

t frequ

ency

Time

Outpu

t frequ

ency

Time

Outpu

t frequ

ency

Time

Outpu

t frequ

ency

Time

Outpu

t frequ

ency

Time

Outpu

t frequ

ency

Time

Outpu

t frequ

ency

Time

Outpu

t frequ

ency

Time

Outpu

t frequ

ency

Time

4 - 3