Siemens 440 User Manual

Page 116

Advertising
background image

Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

116

6SE6400-5BB00-0BP0

P1012[3]

Fixed frequency 12

Min: -650.00

CStat:

CUT

Datatype: Float Unit:

Hz

Def:

55.00

P-Group: SETPOINT

Active: Immediately

QuickComm.: No

Max: 650.00

Defines fixed frequency setpoint 12.

Index:

P1012[0] : 1st. Drive data set (DDS)
P1012[1] : 2nd. Drive data set (DDS)
P1012[2] : 3rd. Drive data set (DDS)

Details:

See parameter P1001 (fixed frequency 1).

P1013[3]

Fixed frequency 13

Min: -650.00

CStat:

CUT

Datatype: Float Unit:

Hz

Def:

60.00

P-Group: SETPOINT

Active: Immediately

QuickComm.: No

Max: 650.00

Defines fixed frequency setpoint 13.

Index:

P1013[0] : 1st. Drive data set (DDS)
P1013[1] : 2nd. Drive data set (DDS)
P1013[2] : 3rd. Drive data set (DDS)

Details:

See parameter P1001 (fixed frequency 1).

P1014[3]

Fixed frequency 14

Min: -650.00

CStat:

CUT

Datatype: Float Unit:

Hz

Def:

65.00

P-Group: SETPOINT

Active: Immediately

QuickComm.: No

Max: 650.00

Defines fixed frequency setpoint 14.

Index:

P1014[0] : 1st. Drive data set (DDS)
P1014[1] : 2nd. Drive data set (DDS)
P1014[2] : 3rd. Drive data set (DDS)

Details:

See parameter P1001 (fixed frequency 1).

P1015[3]

Fixed frequency 15

Min: -650.00

CStat:

CUT

Datatype: Float Unit:

Hz

Def:

65.00

P-Group: SETPOINT

Active: Immediately

QuickComm.: No

Max: 650.00

Defines fixed frequency setpoint 15.

Index:

P1015[0] : 1st. Drive data set (DDS)
P1015[1] : 2nd. Drive data set (DDS)
P1015[2] : 3rd. Drive data set (DDS)

Details:

See parameter P1001 (fixed frequency 1).

P1016[3]

Fixed frequency mode - Bit 0

Min: 1

CStat:

CT

Datatype: U16 Unit:

-

Def:

1

P-Group: SETPOINT

Active: first confirm

QuickComm.: No

Max: 3

Fixed frequencies can be selected in three different modes. Parameter P1016 defines the mode of selection
Bit 0.

Possible Settings:

1 Direct

selection

2

Direct selection + ON command

3

Binary coded selection + ON command

Index:

P1016[0] : 1st. Command data set (CDS)
P1016[1] : 2nd. Command data set (CDS)
P1016[2] : 3rd. Command data set (CDS)

Details:

See table in P1001 (fixed frequency 1) for description of how to use fixed frequencies.

Level

2

Level

2

Level

2

Level

2

Level

3

Advertising