Siemens 440 User Manual

Page 246

Advertising
background image

Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

246

6SE6400-5BB00-0BP0

P2828

BI: NOT 1

Min: 0:0

CStat:

CUT

Datatype: U32 Unit:

-

Def:

0:0

P-Group: TECH

Active: first confirm

QuickComm.: No

Max: 4000:0

P2828 defines input of NOT 1 element, output is P2829.

P2828

r2829

1

C

A

A

C

0

1

1

0

P2800 P2801[9]

Index0

Dependency:

P2801[9] is active level for the NOT element.

r2829

BO: NOT 1

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: TECH

Max: -

Output of NOT 1 element. Displays not logic of bit defined in P2828.

Dependency:

P2801[9] is active level for the NOT element.

P2830

BI: NOT 2

Min: 0:0

CStat:

CUT

Datatype: U32 Unit:

-

Def:

0:0

P-Group: TECH

Active: first confirm

QuickComm.: No

Max: 4000:0

P2830 defines input of NOT 2 element, output is P2831.

Dependency:

P2801[10] is active level for the NOT element.

r2831

BO: NOT 2

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: TECH

Max: -

Output of NOT 2 element. Displays not logic of bit defined in P2830.

Dependency:

P2801[10] is active level for the NOT element.

P2832

BI: NOT 3

Min: 0:0

CStat:

CUT

Datatype: U32 Unit:

-

Def:

0:0

P-Group: TECH

Active: first confirm

QuickComm.: No

Max: 4000:0

P2832 defines input of NOT 3 element, output is P2833.

Dependency:

P2801[11] is active level for the NOT element.

r2833

BO: NOT 3

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: TECH

Max: -

Output of NOT 3 element. Displays not logic of bit defined in P2832.

Dependency:

P2801[11] is active level for the NOT element.

Level

3

Level

3

Level

3

Level

3

Level

3

Level

3

Advertising