Parameter Description

MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0

227

P2218[3]

Fixed PID setpoint mode - Bit 2

Min: 1

CStat:

CT

Datatype: U16 Unit:

-

Def:

1

P-Group: TECH

Active: first confirm

QuickComm.: No

Max: 3

BCD or direct selection Bit 2 for PID setpoint.

Possible Settings:

1 Direct

selection

2

Direct selection + ON command

3

Binary coded selection + ON command

Index:

P2218[0] : 1st. Command data set (CDS)
P2218[1] : 2nd. Command data set (CDS)
P2218[2] : 3rd. Command data set (CDS)

P2219[3]

Fixed PID setpoint mode - Bit 3

Min: 1

CStat:

CT

Datatype: U16 Unit:

-

Def:

1

P-Group: TECH

Active: first confirm

QuickComm.: No

Max: 3

BCD or direct selection Bit 3 for PID setpoint.

Possible Settings:

1 Direct

selection

2

Direct selection + ON command

3

Binary coded selection + ON command

Index:

P2219[0] : 1st. Command data set (CDS)
P2219[1] : 2nd. Command data set (CDS)
P2219[2] : 3rd. Command data set (CDS)

P2220[3]

BI: Fixed PID setp. select Bit 0

Min: 0:0

CStat:

CT

Datatype: U32 Unit:

-

Def:

0:0

P-Group: COMMANDS

Active: first confirm

QuickComm.: No

Max: 4000:0

Defines command source of fixed PID setpoint selection Bit 0

Index:

P2220[0] : 1st. Command data set (CDS)
P2220[1] : 2nd. Command data set (CDS)
P2220[2] : 3rd. Command data set (CDS)

Common Settings:

722.0 = Digital input 1 (requires P0701 to be set to 99, BICO)
722.1 = Digital input 2 (requires P0702 to be set to 99, BICO)
722.2 = Digital input 3 (requires P0703 to be set to 99, BICO)
722.3 = Digital input 4 (requires P0704 to be set to 99, BICO)
722.4 = Digital input 5 (requires P0705 to be set to 99, BICO)
722.5 = Digital input 6 (requires P0706 to be set to 99, BICO)
722.6 = Digital input 7 (via analog input 1, requires P0707 to be set to 99)
722.7 = Digital input 8 (via analog input 2, requires P0708 to be set to 99)

P2221[3]

BI: Fixed PID setp. select Bit 1

Min: 0:0

CStat:

CT

Datatype: U32 Unit:

-

Def:

0:0

P-Group: COMMANDS

Active: first confirm

QuickComm.: No

Max: 4000:0

Defines command source of fixed PID setpoint selection Bit 1.

Index:

P2221[0] : 1st. Command data set (CDS)
P2221[1] : 2nd. Command data set (CDS)
P2221[2] : 3rd. Command data set (CDS)

Common Settings:

722.0 = Digital input 1 (requires P0701 to be set to 99, BICO)
722.1 = Digital input 2 (requires P0702 to be set to 99, BICO)
722.2 = Digital input 3 (requires P0703 to be set to 99, BICO)
722.3 = Digital input 4 (requires P0704 to be set to 99, BICO)
722.4 = Digital input 5 (requires P0705 to be set to 99, BICO)
722.5 = Digital input 6 (requires P0706 to be set to 99, BICO)

Level

3

Level

3

Level

3

Level

3