Issue 01/06 parameter description – Siemens 440 User Manual

Page 159

Advertising
background image

Issue 01/06

Parameter Description

MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0

159

P1316[3]

Boost end frequency

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

%

Def:

20.0

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 100.0

Defines point at which programmed boost reaches 50 % of its value. This value is expressed in [%] relative
to P0310 (rated motor frequency).

The default frequency is defined as follows:

)

3

P

153

(

2

=

f

motor

min

Boost

+

Index:

P1316[0] : 1st. Drive data set (DDS)
P1316[1] : 2nd. Drive data set (DDS)
P1316[2] : 3rd. Drive data set (DDS)

Note:

-

The expert user may change this value to alter the shape of the curve, e.g. to increase torque at a
particular frequency.

-

Default value is depending on inverter type and its rating data.

Details:

See diagram in P1310 (continuous boost).

P1320[3]

Programmable V/f freq. coord. 1

Min: 0.00

CStat:

CT

Datatype: Float Unit:

Hz

Def:

0.00

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 650.00

Sets V/f coordinates (P1320/1321 to P1324/1325) to define V/f characteristic.

V

P1325

f1

P1320

f

max

P1082

V

max

r0071

V

n

P0304

P1323

P1321
P1310

f0

0 Hz

f2

P1322

f3

P1324

f

n

P0310

f

]

P0304[V

100[%]

r0395[%]

100[%]

P1310[%]

P1310[V]

=

V

max

= f(V

dc

, M

max

)

Index:

P1320[0] : 1st. Drive data set (DDS)
P1320[1] : 2nd. Drive data set (DDS)
P1320[2] : 3rd. Drive data set (DDS)

Example:

This parameter can be used to provide correct torque at correct frequency and is useful when used with
synchronous motors.

Dependency:

To set parameter, select P1300 = 3 (V/f with programmable characteristic).

Note:

Linear interpolation will be applied between the individual data points.

V/f with programmable characteristic (P1300 = 3) has 3 programmable points. The two non-programmable
points are:
-

Continuous boost P1310 at zero 0 Hz

-

Rated motor voltage P0304 at rated motor frequency P0310


The acceleration boost and starting boost defined in P1311 and P1312 are applied to V/f with
programmable characteristic.

Level

3

Level

3

Advertising