Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

202

6SE6400-5BB00-0BP0

r2026[2]

USS character frame error

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: COMM

Max: -

Displays number of USS character frame errors.

Index:

r2026[0] : Serial interface COM link
r2026[1] : Serial interface BOP link

r2027[2]

USS overrun error

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: COMM

Max: -

Displays number of USS telegrams with overrun error.

Index:

r2027[0] : Serial interface COM link
r2027[1] : Serial interface BOP link

r2028[2]

USS parity error

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: COMM

Max: -

Displays number of USS telegrams with parity error.

Index:

r2028[0] : Serial interface COM link
r2028[1] : Serial interface BOP link

r2029[2]

USS start not identified

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: COMM

Max: -

Displays number of USS telegrams with unidentified start.

Index:

r2029[0] : Serial interface COM link
r2029[1] : Serial interface BOP link

r2030[2]

USS BCC error

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: COMM

Max: -

Displays number of USS telegrams with BCC error.

Index:

r2030[0] : Serial interface COM link
r2030[1] : Serial interface BOP link

r2031[2] USS

length

error

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: COMM

Max: -

Displays number of USS telegrams with incorrect length.

Index:

r2031[0] : Serial interface COM link
r2031[1] : Serial interface BOP link

r2032

BO: CtrlWrd1 from BOP link (USS)

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: COMM

Max: -

Displays control word 1 from BOP link (word 1 within USS).

Bitfields:

Bit00 ON/OFF1 0 NO 1 YES
Bit01 OFF2: Electrical stop 0 YES 1 NO
Bit02 OFF3: Fast stop 0 YES 1 NO
Bit03 Pulses enabled 0 NO 1 YES

Bit04 RFG enable 0 NO 1 YES
Bit05 RFG start 0 NO 1 YES
Bit06 Setpoint enable 0 NO 1 YES
Bit07 Fault acknowledge 0 NO 1 YES

Bit08 JOG right 0 NO 1 YES
Bit09 JOG left 0 NO 1 YES
Bit10 Control from PLC 0 NO 1 YES
Bit11 Reverse (setpoint inversion) 0 NO 1 YES

Bit13 Motor potentiometer MOP up 0 NO 1 YES
Bit14 Motor potentiometer MOP down 0 NO 1 YES
Bit15 CDS Bit 0 (Local/Remote) 0 NO 1 YES