Issue 01/06 function diagrams – Siemens 440 User Manual

Page 281

Advertising
background image

Issue 01/06

Function Diagrams

MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0

281

- 4150 -

F

unc

tion di

agr

am

8

7

6

5

4

3

2

1

415

0_S

TW1

.v

sd

T

ec

hnol

ogy

F

un

cti

ons

M

IC

R

O

M

AST

ER

440

16.01

.2

006

V

2.1

Control w

ord 1

(r

0054)

1)

(1

:0

)

BI: 1. OF

F2

P0844.C

(1

9:1)

BI: 2. OF

F2

P0845.C

(1:

0)

B

I: Pul

se ena

bl

ing

P0852.C

(1:

0)

BI: R

F

G enable

P1140.C

(1:

0)

BI: R

F

G start

P1141.C

(1:

0)

BI:R

FG enable setp

P1142.C

1

(722:2)

BI:

1. Fau

lts ackn

P2103.C

(0

:0

)

BI:

2. Fau

lts ackn

P2104.C

(0:

0)

B

I: Enable J

OG -

>

P1055.C

(0:

0)

B

I: Enable J

OG <

-

P1056.C

(19:1

3)

BI: Enable MOP(U

P

)

P1035.C

(19:1

4)

BI:Enable MOP(

DWN)

P1036.C

(0:

0)

BI: C

D

S b0 loc/rem

P0810

T

he sequence contr

ol

is the inter

nal

contr

ol

(

softwar

e) f

or r

eali

zing the

inverter

status (r

0001)

CO/BO

: A

ct

C

trlWd1

r005

4

r005

4

Sequence contr

ol

1

)

Braking contro

l

Setpoint channel

Sequence contr

ol

1

)

Braking contro

l

Sequence contr

ol

1

)

Braking contro

l

Setpoint channel

Sequence contr

ol

1

)

Sequence contr

ol

1

)

Setpoint channel

Setpoint channel

Setpoint channel

Sequence contr

ol

1

)

Setpoint channel

Sequence contr

ol

1

)

Setpoint channel

Setpoint channel

Setpoint channel

Setpoint channel

Sequence contr

ol

1

)

Note:T

his

bit must be

s

et

in

th

e fi

rs

t PZD

wor

d of the

tel

eg

ram r

ecei

ved f

rom ser

ial inter

fac

e

s,

so

th

at the converte

r will

a

ccept th

e process data as being

va

lid (compa

re U

S

S,

P

R

OFIBUS,

etc

.)

BOP/AO

P via "

F

n"

1 0

3

2

5 4

7 6

9 8

11

10

13 12

15 1

4

Segme

nt Bi

t

Segme

nt Bi

t

Seve

n-

segm

en

t d

ispla

y

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

0

Bit

No.

(722:0)

BI: ON/OFF

1

P08

40.C

(0:0)

BI

:O

N

re

ve

rs

e/

OF

F1

P08

42.C

1

(1

:0

)

BI: 1. OF

F3

P0848.C

(1

:0

)

BI: 2. OF

F3

P0849.C

(0:0)

BI

:O

N

re

ve

rs

e/

OF

F1

P08

42.C

(722:1)

BI: Rever

se

P11

13.C

1

All bi

ts =

1 -

->

dr

iv

e r

uns

Mea

n

in

g

0

= ON

/O

F

F

1

, Shutdown

v

ia r

amp, followed b

y pu

ls

e disabl

e

1

= ON

, opera

tin

g

c

on

di

tion (

edge-

co

ntrolled)

0

= OF

F2: Electrical s

top

, puls

e d

isable, moto

r coasts down

1

= Oper

ating conditi

o

n

0

= OFF

3: Fast stop

1

= Oper

ating conditi

o

n

Para

m

eter r00

54

1

= Pulse enable

0

= Pulse dis

a

bl

e

1

= R

F

G enab

le

0 =

S

et R

F

G

to

0

1 =

RF

G

s

ta

rt

0 =

S

top

R

F

G

1

= R

F

G setpoint enab

le

0

= Set

poi

n

t di

sable

0 =

No

1

= F

ault ack

n

owledge

0 =

NO

1

= JOG r

ight

0 =

NO

1

= JOG l

ef

t

1

= C

ontr

ol

fr

om PLC

0

= N

o contro

l fr

om PLC

1

= R

everse (

setp

oi

nt

in

ver

sion)

0

= R

evers dis

a

bl

ed

re

se

rv

ed

0 =

NO

1

= M

otor p

otentiometer

MOP up

0 =

NO

1

= M

otor p

otentiometer

MOP down

0 =

NO

1

= C

D

S Bit 0 (local/rem

ote)

&

&

Advertising