Parameter Description

MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0

35

t

r0054

Bit00

ON/OFF1

ON

t

r0054

Bit11

Reverse

0

t

f

act

t

r0052
Bit02

Drive running

t

r0052
Bit14

Motor runs

right

left

not defined
last state is displayed

r0052 Bit14 "Motor runs right" ==> see below

Details:

The 7-segment display of the bit-parameters (binary parameters) is explained in the Introduction of the
Parameter List.

r0053

CO/BO: Act. status word 2

Min: -

Datatype: U16 Unit:

-

Def:

-

P-Group: COMMANDS

Max: -

Displays second status word of inverter (in bit format).

Bitfields:

Bit00 DC brake active 0 NO 1 YES
Bit01 f_act > P2167 (f_off) 0 NO 1 YES
Bit02 f_act <= P1080 (f_min) 0 NO 1 YES
Bit03 Act. current r0027 > P2170 0 NO 1 YES

Bit04 f_act > P2155 (f_1) 0 NO 1 YES
Bit05 f_act <= P2155 (f_1) 0 NO 1 YES
Bit06 f_act >= setpoint 0 NO 1 YES
Bit07 Act. Vdc r0026 < P2172 0 NO 1 YES

Bit08 Act. Vdc r0026 > P2172 0 NO 1 YES
Bit09 Ramping finished 0 NO 1 YES
Bit10 PID output r2294 == P2292 (PID_min) 0 NO 1 YES
Bit11 PID output r2294 == P2291 (PID_max) 0 NO 1 YES

Bit14 Download data set 0 from AOP 0 NO 1 YES
Bit15 Download data set 1 from AOP 0 NO 1 YES

Note:

-

r0053 Bit00 ==> see parameter P1233

-

r0053 Bit01 ==> see parameter P2167

-

r0053 Bit02 ==> see parameter P1080

-

r0053 Bit03 ==> see parameter P2170

-

r0053 Bit04 ==> see parameter P2155

-

r0053 Bit05 ==> see parameter P2155

-

r0053 Bit06 ==> see parameter P2150

-

r0053 Bit07 ==> see parameter P2172

-

r0053 Bit08 ==> see parameter P2172