Parameter Description

MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0

133

P1130[3]

Ramp-up initial rounding time

Min: 0.00

CStat:

CUT

Datatype: Float Unit:

s

Def:

0.00

P-Group: SETPOINT

Active: first confirm

QuickComm.: No

Max: 40.00

Defines initial rounding time in seconds as shown on the diagram below.

P1133

P1132

P1131

P1130

t

f

f

2

f

1

t

up

t

down


where:

for

P1131)

P1130

(

2

1

P1120

P1082

f

-

f

1

2

+

P1120

P1082

f

-

f

P1131)

P1130

(

2

1

t

1

2

up

+

+

=

for

P1133)

P1132

(

2

1

P1121

P1082

f

-

f

1

2

+

P1121

P1082

f

-

f

P1133)

P1132

(

2

1

t

1

2

down

+

+

=

Index:

P1130[0] : 1st. Drive data set (DDS)
P1130[1] : 2nd. Drive data set (DDS)
P1130[2] : 3rd. Drive data set (DDS)

Note:

-

If short or zero ramp times (P1120, P1121 < P1130, P1131, P1132, P1133) are set, the total ramp up
time (t_up) or ramp down time (t_down) will not depend on P1130.

-

See equations above for valid conditions to calculate t_up and t_down.

-

Rounding times are recommended, since they prevent an abrupt response, thus avoiding detrimental
effects on the mechanics.

-

Rounding times are not recommended when analog inputs are used, since they would result in
overshoot/undershoot in the inverter response.

P1131[3]

Ramp-up final rounding time

Min: 0.00

CStat:

CUT

Datatype: Float Unit:

s

Def:

0.00

P-Group: SETPOINT

Active: first confirm

QuickComm.: No

Max: 40.00

Defines rounding time at end of ramp-up as shown in P1130 (ramp-up initial rounding time).

Index:

P1131[0] : 1st. Drive data set (DDS)
P1131[1] : 2nd. Drive data set (DDS)
P1131[2] : 3rd. Drive data set (DDS)

Details:

See parameter P1130.

P1132[3]

Ramp-down initial rounding time

Min: 0.00

CStat:

CUT

Datatype: Float Unit:

s

Def:

0.00

P-Group: SETPOINT

Active: first confirm

QuickComm.: No

Max: 40.00

Defines rounding time at start of ramp-down as shown in P1130 (ramp-up initial rounding time).

Index:

P1132[0] : 1st. Drive data set (DDS)
P1132[1] : 2nd. Drive data set (DDS)
P1132[2] : 3rd. Drive data set (DDS)

Details:

See parameter P1130.