Siemens 440 User Manual

Page 144

Advertising
background image

Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

144

6SE6400-5BB00-0BP0

P1232[3] DC

braking

current

Min: 0

CStat:

CUT

Datatype: U16 Unit:

%

Def:

100

P-Group: FUNC

Active: Immediately

QuickComm.: No

Max: 250

Defines level of DC current in [%] relative to rated motor current (P0305).

%

100

P1232

P0305

2

1

[A]

r0027

Brake

DC


The current of the DC-braking is limited by r0067.

Index:

P1232[0] : 1st. Drive data set (DDS)
P1232[1] : 2nd. Drive data set (DDS)
P1232[2] : 3rd. Drive data set (DDS)

P1233[3]

Duration of DC braking

Min: 0.00

CStat:

CUT

Datatype: Float Unit:

s

Def:

0.00

P-Group: FUNC

Active: Immediately

QuickComm.: No

Max: 250.00

Defines duration for which DC injection braking is to be active following an OFF1 or OFF3 command. When
an OFF1 or OFF3 command is received by the drive, the output frequency starts to ramp to 0 Hz. When the
output frequency reaches the value set in P1234, the drive injects a DC braking current P1232 for the time
duration set in P1233.

t

P1234

OFF1/OFF3

ON

t

t

f

P1233

1

tt

P0347

OFF2

DC braking

OFF2

0

1

DC braking active

r0053

Bit00

t

P1234

OFF1/OFF3

ON

t

t

f

OFF ramp

P1233

2

t

OFF2

tt

P0347

OFF2

OFF2

DC braking

0

1

DC braking active

r0053

Bit00

The DC current, that is impressed during time P1233, is specified by parameter P1232.

Level

2

Level

2