Siemens 440 User Manual

Page 41

Advertising
background image

Issue 01/06

Parameter Description

MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0

41

P0095[10] CI: Display PZD signals

Min: 0:0

CStat:

CT

Datatype: U32 Unit:

-

Def:

0:0

P-Group: CONTROL

Active: first confirm

QuickComm.: No

Max: 4000:0

Selects source of display for PZD signals.

Index:

P0095[0] : 1st PZD signal
P0095[1] : 2nd PZD signal
P0095[2] : 3rd PZD signal
P0095[3] : 4th PZD signal
P0095[4] : 5th PZD signal
P0095[5] : 6th PZD signal
P0095[6] : 7th PZD signal
P0095[7] : 8th PZD signal
P0095[8] : 9th PZD signal
P0095[9] : 10th PZD signal

r0096[10] PZD

signals

Min: -

Datatype: Float Unit:

%

Def:

-

P-Group: CONTROL

Max: -

Displays PZD signals in [%].

Index:

r0096[0] : 1st PZD signal
r0096[1] : 2nd PZD signal
r0096[2] : 3rd PZD signal
r0096[3] : 4th PZD signal
r0096[4] : 5th PZD signal
r0096[5] : 6th PZD signal
r0096[6] : 7th PZD signal
r0096[7] : 8th PZD signal
r0096[8] : 9th PZD signal
r0096[9] : 10th PZD signal

Note:

r0096 = 100 % corresponds to 4000 hex.

Level

3

Level

3

Advertising