Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

156

6SE6400-5BB00-0BP0

3.29.1

V/f control technique

P1310[3] Continuous

boost

Min: 0.0

CStat:

CUT

Datatype: Float Unit:

%

Def:

50.0

P-Group: CONTROL

Active: Immediately

QuickComm.: No

Max: 250.0

P1310 causes a voltage boost depending on the output frequency (see diagran). At low output frequencies
the output voltage is low to keep the flux level constant. However, the output voltage may be too low
-

for magnetisation the asynchronous motor

-

to hold the load

-

to overcome losses in the system.


To compensate these effects, the output voltage can be increased using parameter P1310.

Defines boost level in [%] relative to P0305 (rated motor current) applicable to both linear and quadratic V/f
curves according to the diagram below:

f

Linear V/f

OFF

ON

t

t

f

P1310 active

t

0

1

Validity range

Vmax

Vn

(P0304)

V

ConBoost,100

0

fn

(P0310)

f max

(P1082)

V

f

Boost,end

(P1316)

Boost

Ou

tpu

t v

olta

ge

actual V

No

rm

al

V/f

(P

1300

= 0)

V

ConBoost,50

Boost voltage

V

ConBoost,100

V

Vn

(P0304)

Vmax

f

Boost,end

(P1316)

f

0

OFF

ON

t

t

f

P1310 active

t

0

1

Validity range

fn

(P0310)

fmax

(P1082)

Boost

Quadratic V/f

No

rm

al

qu

ad

ra

tic

(P

13

00

=

2

)

V

ConBoost,50

actual V

Ou

tpu

t v

olt

ag

e

Boost voltage


where voltage values are given

100

P1310

0350

P

0305

P

V

100

,

ConBoost

=

2

V

00

ConBoost,1

0

ConBoost,5

V

=

Index:

P1310[0] : 1st. Drive data set (DDS)
P1310[1] : 2nd. Drive data set (DDS)
P1310[2] : 3rd. Drive data set (DDS)

Level

2

Advertising