6SE6400-5BB00-0BP0

P0702[3]

Function of digital input 2

Min: 0

CStat:

CT

Datatype: U16 Unit:

-

Def:

12

P-Group: COMMANDS

Active: first confirm

QuickComm.: No

Max: 99

Selects function of digital input 2.

Possible Settings:

0

Digital input disabled

1 ON/OFF1
2

ON reverse /OFF1

3

OFF2 - coast to standstill

4

OFF3 - quick ramp-down

9 Fault

acknowledge

10 JOG

right

11 JOG

left

12 Reverse
13 MOP up (increase frequency)
14 MOP down (decrease frequency)
15 Fixed setpoint (Direct selection)
16 Fixed setpoint (Direct selection + ON)
17 Fixed setpoint (Binary coded selection + ON)
25 DC brake enable
29 External

trip

33 Disable additional freq setpoint
99 Enable BICO parameterization

Index:

P0702[0] : 1st. Command data set (CDS)
P0702[1] : 2nd. Command data set (CDS)
P0702[2] : 3rd. Command data set (CDS)

Details:

See P0701 (function of digital input1).

P0703[3]

Function of digital input 3

Min: 0

CStat:

CT

Datatype: U16 Unit:

-

Def:

9

P-Group: COMMANDS

Active: first confirm

QuickComm.: No

Max: 99

Selects function of digital input 3.

Possible Settings:

0

Digital input disabled

1 ON/OFF1
2

ON reverse /OFF1

3

OFF2 - coast to standstill

4

OFF3 - quick ramp-down

9 Fault

acknowledge

10 JOG

right

11 JOG

left

12 Reverse
13 MOP up (increase frequency)
14 MOP down (decrease frequency)
15 Fixed setpoint (Direct selection)
16 Fixed setpoint (Direct selection + ON)
17 Fixed setpoint (Binary coded selection + ON)
25 DC brake enable
29 External

trip

33 Disable additional freq setpoint
99 Enable BICO parameterization

Index:

P0703[0] : 1st. Command data set (CDS)
P0703[1] : 2nd. Command data set (CDS)
P0703[2] : 3rd. Command data set (CDS)

Details:

See P0701 (function of digital input 1).