Parameter Description

Issue 01/06

MICROMASTER 440 Parameter List

174

6SE6400-5BB00-0BP0

Caution:

Be aware, by changing of parameter P1500 all BICO parameters (see table below) are modified.

Note:

Changing this parameter sets (to default) all settings on item selected (see table).

P1500 = xy

y = 0

y = 2

y = 4

y = 5

y = 6

y = 7

0.0 755.0

2015.1

2018.1

2050.1

755.1 P1503

x = 0

0.0 0.0

0.0

0.0

0.0

0.0 P1511

0.0 755.0

2015.1

2018.1

2050.1

755.1 P1503

x = 2

755.0 755.0

755.0

755.0

755.0

755.0 P1511

0.0 755.0

2015.1

2018.1

2050.1

755.1 P1503

x = 4

2015.1 2015.1

2015.1

2015.1

2015.1

2015.1 P1511

0.0 755.0

2015.1

2018.1

755.1 P1503

x = 5

2018.1 2018.1

2018.1

2018.1

2018.1 P1511

0.0 755.0

2015.1

2050.1

755.1 P1503

x = 6

2050.1 2050.1

2050.1

2050.1

2050.1 P1511

0.0 755.0

2015.1

2018.1

2050.1

755.1 P1503

P

150

0 = x

y

x = 7

755.1 755.1

755.1

755.1

755.1

755.1 P1511

Example:

P1500 = 24

P1503 = 2015.1
P1511 = 755.0