6SE6400-5BB00-0BP0

A0510 Motor

overtemperature

A0511 Motor

overtemperature

Cause

-

motor is overloaded.

-

load duty cycle is exceeded.

Diagnosis & Remedy

Check, independently of the type of temperature monitoring:
-

P0604 alarm threshold, motor overtemperature

-

P0625 motor ambient temperature

If P0601 = 0 or 1, please check the following:
-

is the motor data correct (rating plate)?, if not, carry-out a fast commissioning routine

-

precise temperature values from the motor identification routine (P1910=1).

-

is the motor weight correct (P0344)?

-

the permissible overtemperature can be changed using P0626, P0627, P0628, if the motor is not a
standard Siemens motor.

If P0601 = 2, then please check the following:
-

is the temperature displayed in r0035 plausible?

-

is an KTY84 temperature sensor being used? (others are not supported).

A0520 Rectifier

overtemperature

Cause

-

alarm threshold of the rectifier heatsink exceeded.

Diagnosis & Remedy

Please check the following:
-

is the ambient temperature within the permissible range ?

-

are the load and load duty cycle within the permissible range ?

-

does the fan operate if the inverter is operational ?

A0521 Ambient temperature too high

Cause

-

alarm threshold of the permissible ambient temperature exceeded.

Diagnosis & Remedy

Please check the following:
-

is the ambient temperature within the permissible range ?

-

does the fan operate if the inverter is operational ?

-

is the air feed to the fan obstructed ?

A0522 Read I2C, time exceeded

Cause

-

cyclic access to UCE values and power module data via i2c bus (only for sizes FX and GX) is faulted.

A0523 Output

fault

Cause

-

an output cable is not connected.

Diagnosis & Remedy

-

alarm can be suppressed.

A0535 Brake resistor hot

Cause

-

the load duty cycle of the braking resistor has been exceeded.

-

when the load duty cycle is exceeded, then it is automatically limited to the value P1237.

Diagnosis & Remedy

-

use a braking resistor with higher power rating / higher load duty cycle.

A0541 Motor data identification routine active

Cause

-

motor data identification routine (P1910) selected and is active

A0542 Speed controller optimization running

Cause

-

speed controller optimization (P1960) is selected and is presently active.